BROWNSVILLE, TX —
OSHA Inspection: STEELCOAST COMPANY, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STEELCOAST COMPANY, LLC in 16200 JOE GARZA SR. RD., BROWNSVILLE, TX 78521 (NAICS 423930). OSHA activity number 345787139.
Where did this inspection happen?
- Establishment
- STEELCOAST COMPANY, LLC
- Site address
- 16200 JOE GARZA SR. RD.
- City
- BROWNSVILLE
- State
- TX
- ZIP
- 78521
- Mailing
- 16200 JOE GARZA SR. RD., BROWNSVILLE, TX 78521
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 223
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.212 B
- Issued
- Penalty
- Initial $5594.00 · Current $3356.00 Reduced
General-duty citation text
29 CFR 1910.212(b):Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: On or about February 15, 2022, and times prior there to, in the Wire Chopper Building, the air compressor machine, tower trash conveyor, and copper transport conveyor were not anchored and or secured to stop walking and movement during operation. a) Quincy compressor b)Tower Trash Conveyor machine wheels c) Copper Transport Conveyor
Recent events (2)
- — I (S) $3356
- — Z (S) $5594
1910.242 B
- Issued
- Penalty
- Initial $5594.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 P.S.I. : On or about February 15, 2022, and times prior there to, in the Wire Chopper Building, the compressor air machine used by employees to air clean the work area was not reduced to less than 30 P.S.I. .
Recent events (2)
- — I (O) $0
- — Z (S) $5594
1917.154
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1917.154: Compressed air was used to clean employees: On or about February 15, 2022, and times prior there to, in the Wire Chopper Building, compressed air from the compressor air machine was allowed to be used for work area and self cleaning purposes by employees.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.303 G02 I
- Issued
- Penalty
- Initial $9324.00 · Current $4662.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): On or about February 15, 2022, and times prior there to, in the Wire Chopper Building, an electrical-panel-junction-box was not guarded against contact by live electrical wiring, exposing employees to serious injury and possibly death.
Recent events (2)
- — I (S) $4662
- — Z (S) $9324
1910.305 B02 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: On or about February 15, 2022, and times prior there to, in the Wire Chopper Building, the employer did not ensure the electrical outlet used to energize the negative machine was covered exposing employees to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: On or about February 15, 2022, and times prior there to, in the Wire Chopper Building, employer failed to post exit signs to indicate the nearest direction of exit for a work site employee evacuation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at STEELCOAST COMPANY, LLC
BROWNSVILLE, TX—2022-02-15 00:00:00
STEELCOAST COMPANY, LLC
BROWNSVILLE, TX—2022-02-15 00:00:00
STEELCOAST COMPANY, LLC
BROWNSVILLE, TX—2022-02-15 00:00:00
STEELCOAST COMPANY, LLC
BROWNSVILLE, TX—2022-02-15 00:00:00
STEELCOAST COMPANY, LLC
BROWNSVILLE, TX—2022-02-15 00:00:00
STEELCOAST COMPANY, LLC
View STEELCOAST COMPANY, LLC's full OSHA safety record →
More inspections in this industry (NAICS 423930)
DETROIT, MI—2026-07-15
STRONG STEEL PRODUCTS, LLC
OGDEN, UT—2026-07-10
TEAR A PART AUTO RECYCLING
GARNER, NC—2026-07-09
161490 - CAROLINA METAL RECYCLERS, LLC
JOPLIN, MO—2026-07-07
SERVICE RECYCLING - NORTH PLANT
HOLBROOK, NY—2026-07-01
ARROW SCRAP CORPORATION
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345787139.