Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EVERETT HANNAH LUMBER INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EVERETT HANNAH LUMBER INC. in ROUTE 52, VARNEY, WV 25696 (NAICS 321113). OSHA activity number 345788210.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Everett Hannah Lumber INC. — free Get an email when a new federal OSHA severe-injury report for Everett Hannah Lumber INC. is published. One employer, no account, unsubscribe in one click.
Site address
ROUTE 52
City
VARNEY
State
WV
ZIP
25696
Mailing
P.O. BOX 277, VARNEY, WV 25696
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
13
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 8, 2022
Abate by
Apr 1, 2022
Penalty
Initial $4,144 · Current $4,144
29 CFR  1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  (a)  Facility Wide:  On February 16, 2022 and times prior, employee conduct maintenance activities on equipment such as but not limited to, the chipper and the edger.  The employer has not established and developed an energy control program to protect employees from the unexpected start up of equipment during maintenance activities.
Recent events (2)
  • — I (S) $4144
  • — Z (S) $4144

1910.147 D04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 8, 2022
Abate by
Apr 1, 2022
Penalty
Initial $4,144 · Current $0 Reduced
29 CFR  1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a)  Facility Wide:  On February 16, 2022 and times prior, employee conduct maintenance activities on equipment such as but not limited to, the chipper and the edger.  The employer did not ensure that authorized employees were affixing lockout devices to 480 volt energy isolation devices prior to conducted maintenance activities on equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4144

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345788210.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.