Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TOTAL AIR SUPPLY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TOTAL AIR SUPPLY, INC. in 1 B STREET, DERRY, NH 03038 (NAICS 423730). OSHA activity number 345791008.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Total AIR Supply, INC. — free Get an email when a new federal OSHA severe-injury report for Total AIR Supply, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1 B STREET
City
DERRY
State
NH
ZIP
03038
Mailing
1 B STREET, DERRY, NH 03038
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423730
Employees
64
Ownership type
A

9 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 60 exposed
Issued
Jul 13, 2022
Abate by
Aug 8, 2022
Penalty
Initial $7,252 · Current $3,626 Reduced
29 CFR  1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items (a) through (d) of this section:  Location:  Sheet metal shop. a. On or about February 27, 2022, the employer failed to ensure that lockout-tagout procedures for the coil line included requirements for testing/verifying the effectiveness of lockout devices.
Recent events (2)
  • — I (S) $3626
  • — Z (S) $7252

1910.147 C06 I

Serious Gravity 5 1 instance 60 exposed
Issued
Jul 13, 2022
Abate by
Aug 8, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:   Location:  Sheet metal shop. a. On or about February 27, 2022, the employer failed to ensure that lockout-tagout procedures for the coil line were inspected at least annually.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 A04

Serious Gravity 5 1 instance 60 exposed
Issued
Jul 13, 2022
Abate by
Aug 29, 2022
Penalty
Initial $7,252 · Current $3,626 Reduced
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:  Location:  Sheet metal shop. a. On or about February 27, 2022, prior written approval was not obtained for the coil lifting device used on the Caterpillar, Model T125D, Serial No. 5MB03113.
Recent events (2)
  • — I (S) $3626
  • — Z (S) $7252

1910.212 A03 II

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 13, 2022
Penalty
Initial $7,252 · Current $3,626 Reduced
29 CFR  1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  Location:  Sheet metal shop  a. On or about February 27, 2022, the employer did not ensure employees operating a Engle sheet metal bender were protected from crushing/amputation hazards. b. On or about February 27, 2022, the employer did not ensure employees operating a Roto-Die, Inc. press brake were protected from crushing/amputation hazards.
Recent events (2)
  • — I (S) $3626
  • — Z (S) $7252

1910.219 F03

Serious Gravity 10 2 instances 2 exposed
Issued
Jul 13, 2022
Penalty
Initial $10,151 · Current $5,076 Reduced
29 CFR  1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed:  Location:  Sheet metal shop. a. On or about February 27, 2022, the in-running nip points on the sprocket wheels and chain of the Iowa Precision Line-O-Matic, Model IM550-GIN, Serial Number IM0805  were not enclosed. b. On or about February 27, 2022, the in-running nip points on the sprocket wheels and chain of the Engle Female Form Roller were not enclosed.
Recent events (2)
  • — I (S) $5075.5
  • — Z (S) $10151

1910.219 K01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 13, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.219(k)(1): Clutches, cutoff couplings, or clutch pulleys had projecting parts which were not enclosed by a stationary guard:  Location:  Sheet metal shop. a. On or about February 27, 2022, the coil line clutch mechanism was not enclosed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B01 VIII

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 13, 2022
Penalty
Initial $5,801 · Current $2,901 Reduced
29 CFR  1910.303(b)(1)(viii): Electrical equipment was not free from recognized hazards based on other factors that contribute to the practical safeguarding of persons using or likely to come in contact with the equipment:   Location:  Sheet metal shop  a. On or about February 17, 2022, the employer failed to ensure that the electric conductors on top of the coil reducer clutch were protected from contact by employees.
Recent events (2)
  • — I (S) $2900.5
  • — Z (S) $5801

1910.303 B02

Other-than-serious 2 instances 60 exposed
Issued
Jul 13, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Location:  Sheet metal shop  a. On or about March 24, 2022, the electrical connectors on top of the clutch mechanism of the coil clutch/reducer were not protected  . b. On or about March 24, 2022, a relocatable power tap was plugged into an extension cord.  The UL listing 1363 requires relocatable power taps be plugged directly into an outlet receptacle.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 60 exposed
Issued
Jul 13, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:   Location:  Sheet metal shop  a. On or about March 24, 2022, a relocatable power tap was plugged into an extension cord which was fastened to a pendant cord.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Total AIR Supply, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345791008.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.