DERRY, NH —
OSHA Inspection: TOTAL AIR SUPPLY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TOTAL AIR SUPPLY, INC. in 1 B STREET, DERRY, NH 03038 (NAICS 423730). OSHA activity number 345791008.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TOTAL AIR SUPPLY, INC.
- Site address
- 1 B STREET
- City
- DERRY
- State
- NH
- ZIP
- 03038
- Mailing
- 1 B STREET, DERRY, NH 03038
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423730
- Employees
- 64
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.147 C04 II
- Issued
- Jul 13, 2022
- Abate by
- Aug 8, 2022
- Penalty
- Initial $7,252 · Current $3,626 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items (a) through (d) of this section: Location: Sheet metal shop. a. On or about February 27, 2022, the employer failed to ensure that lockout-tagout procedures for the coil line included requirements for testing/verifying the effectiveness of lockout devices.
Recent events (2)
- — I (S) $3626
- — Z (S) $7252
1910.147 C06 I
- Issued
- Jul 13, 2022
- Abate by
- Aug 8, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: Location: Sheet metal shop. a. On or about February 27, 2022, the employer failed to ensure that lockout-tagout procedures for the coil line were inspected at least annually.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 A04
- Issued
- Jul 13, 2022
- Abate by
- Aug 29, 2022
- Penalty
- Initial $7,252 · Current $3,626 Reduced
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: Location: Sheet metal shop. a. On or about February 27, 2022, prior written approval was not obtained for the coil lifting device used on the Caterpillar, Model T125D, Serial No. 5MB03113.
Recent events (2)
- — I (S) $3626
- — Z (S) $7252
1910.212 A03 II
- Issued
- Jul 13, 2022
- Penalty
- Initial $7,252 · Current $3,626 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): Location: Sheet metal shop a. On or about February 27, 2022, the employer did not ensure employees operating a Engle sheet metal bender were protected from crushing/amputation hazards. b. On or about February 27, 2022, the employer did not ensure employees operating a Roto-Die, Inc. press brake were protected from crushing/amputation hazards.
Recent events (2)
- — I (S) $3626
- — Z (S) $7252
1910.219 F03
- Issued
- Jul 13, 2022
- Penalty
- Initial $10,151 · Current $5,076 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: Location: Sheet metal shop. a. On or about February 27, 2022, the in-running nip points on the sprocket wheels and chain of the Iowa Precision Line-O-Matic, Model IM550-GIN, Serial Number IM0805 were not enclosed. b. On or about February 27, 2022, the in-running nip points on the sprocket wheels and chain of the Engle Female Form Roller were not enclosed.
Recent events (2)
- — I (S) $5075.5
- — Z (S) $10151
1910.219 K01
- Issued
- Jul 13, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(k)(1): Clutches, cutoff couplings, or clutch pulleys had projecting parts which were not enclosed by a stationary guard: Location: Sheet metal shop. a. On or about February 27, 2022, the coil line clutch mechanism was not enclosed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B01 VIII
- Issued
- Jul 13, 2022
- Penalty
- Initial $5,801 · Current $2,901 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(viii): Electrical equipment was not free from recognized hazards based on other factors that contribute to the practical safeguarding of persons using or likely to come in contact with the equipment: Location: Sheet metal shop a. On or about February 17, 2022, the employer failed to ensure that the electric conductors on top of the coil reducer clutch were protected from contact by employees.
Recent events (2)
- — I (S) $2900.5
- — Z (S) $5801
1910.303 B02
- Issued
- Jul 13, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Location: Sheet metal shop a. On or about March 24, 2022, the electrical connectors on top of the clutch mechanism of the coil clutch/reducer were not protected . b. On or about March 24, 2022, a relocatable power tap was plugged into an extension cord. The UL listing 1363 requires relocatable power taps be plugged directly into an outlet receptacle.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Jul 13, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Location: Sheet metal shop a. On or about March 24, 2022, a relocatable power tap was plugged into an extension cord which was fastened to a pendant cord.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Total AIR Supply, INC.
View Total AIR Supply, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423730)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345791008.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.