Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COZMYK ENTERPRISES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COZMYK ENTERPRISES, INC. in 3757 COURTRIGHT COURT, COLUMBUS, OH 43227 (NAICS 332312). OSHA activity number 345800239.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cozmyk Enterprises, INC. — free Get an email when a new federal OSHA severe-injury report for Cozmyk Enterprises, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3757 COURTRIGHT COURT
City
COLUMBUS
State
OH
ZIP
43227
Mailing
3757 COURTRIGHT COURT, COLUMBUS, OH 43227
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
15
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 29, 2022
Abate by
Jun 21, 2022
Penalty
Initial $4,144 · Current $2,279 Reduced
29 CFR  1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) Cozmyk Enterprises, Inc. located at 3757 Courtright Court COLUMBUS, OH 43227:  On and preceding February 24, 2022, the employer did not ensure that procedures were developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in die setting and maintenance activities on machinery which included but is not limited to hydraulic press brakes and laser CNC machines.  The following condition exposed employees to caught-in and struck-by hazards.
Recent events (2)
  • — I (S) $2279.2
  • — Z (S) $4144

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 29, 2022
Abate by
Jun 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   a) Cozmyk Enterprises, Inc. located at 3757 Courtright Court COLUMBUS, OH 43227:  On and preceding February 24, 2022, the employer did not conduct a periodic inspection of the energy control procedures at least annually to ensure that the procedures and the requirements of this standard were being followed. Employees were engaged in die setting and maintenance activities on machinery which included but is not limited to hydraulic press brakes and laser CNC machines.   An inspection of the hazardous energy control program had not been performed to ensure that it was being properly utilized. The following condition exposed employees to caught-in and struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 29, 2022
Abate by
Jun 21, 2022
Penalty
Initial $4,144 · Current $2,279 Reduced
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):   a) Cozmyk Enterprises, Inc. located at 3757 Courtright Court COLUMBUS, OH 43227:  On and preceding February 24, 2022, employees were exposed to machine hazards associated with moving parts during servicing, maintenance and die setting activities on machinery which included but is not limited to hydraulic press brakes and laser CNC machines.  The employer failed to implement energy control application steps as LOTO devices were not applied to the electrical disconnect [per the 1910.147(d)(4) requirements]. As a result, the remaining applicable energy control elements, involving dissipation of residual energy [(d)(S)(i)J, and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards. The following condition exposed employees to caught-in and struck-by hazards.
Recent events (2)
  • — I (S) $2279.2
  • — Z (S) $4144

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 29, 2022
Abate by
Jun 21, 2022
Penalty
Initial $4,144 · Current $2,279 Reduced
29 CFR  1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):(   a) Cozmyk Enterprises, Inc. located at 3757 Courtright Court COLUMBUS, OH 43227:  On and preceding February 24, 2022, the employer did not ensure that a Gasparini PBS 165 hydraulic press brake was guarded to prevent employees from having any part of their body in the danger zone during operating cycle.  Employees used the press brake for various size materials  including but not limited to long aluminum angled pieces without a method in place for guarding the point of operation such as  light curtains, two-handed controls or any form of documented administrative controls thereby exposing employees to caught-in hazards.
Recent events (2)
  • — I (S) $2279.2
  • — Z (S) $4144

1910.101 B

Other-than-serious 1 instance 12 exposed
Issued
Apr 29, 2022
Abate by
Jun 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:   a) Cozmyk Enterprises, Inc. located at 3757 Courtright Court COLUMBUS, OH 43227:  On and preceding February 24, 2022, the employer did not ensure that compressed gas cylinders of different types and charged versus empty cylinders were separated.  Employees used various types of compressed gasses for welding and other machinery which were all stored in the same location regardless of whether they were empty or charged.  Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: 3.3.3 states that Where gases of different types are stored at the same location, cylinders should be grouped by types of gas and the groups arranged to take into account the gases contained, e.g. flammable gases should not be stored near oxidizing gases. 3.3.4: Charged and empty cylinders should be stored separately with the storage layout so planned that cylinders comprising old stock can be removed first with a minimum handling of other cylinders.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 12 exposed
Issued
Apr 29, 2022
Abate by
Jun 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:   a) Cozmyk Enterprises, Inc. located at 3757 Courtright Court COLUMBUS, OH 43227:  On and preceding February 24, 2022, the employer did not develop, implement, and maintain a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met. Employees perform welding, painting, sanding and use other various chemicals  as a part of the daily processes in the industrial area.  The written hazard communication program was not implemented and maintained to address chemicals used while completing industrial processes throughout the facility.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G08

Other-than-serious 1 instance 12 exposed
Issued
Apr 29, 2022
Abate by
Jun 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical:   a) Cozmyk Enterprises, Inc. located at 3757 Courtright Court COLUMBUS, OH 43227:  On and preceding February 24, 2022,  the employer did not ensure that required safety data sheets for each hazardous chemical were made available at the work site. Employees perform welding, painting, sanding and use other various chemicals as a part of the daily processes in the industrial area. The written hazard communication program did was not maintained to ensure that the material safety data sheets (MSDS's) were updated to safety data sheets(SDS's).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Cozmyk Enterprises, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345800239.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.