PORT ARANSAS, TX —
OSHA Inspection: PARADISE PALM CONSTRUCTION, LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of PARADISE PALM CONSTRUCTION, LLC in 3087 SOUTH 11TH STREET, PORT ARANSAS, TX 78373 (NAICS 236115). OSHA activity number 345809214.
Where did this inspection happen?
- Establishment
- PARADISE PALM CONSTRUCTION, LLC
- Site address
- 3087 SOUTH 11TH STREET
- City
- PORT ARANSAS
- State
- TX
- ZIP
- 78373
- Mailing
- 5926 SOUTH STAPLES SUITE A, CORPUS CHRISTI, TX 78413
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.100 A
- Issued
- Penalty
- Initial $3108.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns. On or about February 8, 2022, at this work place, employees conducting framing operations from scaffolding more than 10 feet above a lower level and employees working below the scaffolds were not protected by protective helmets while working in areas where there was possible danger of head injury from impact, or from falling or flying objects. a) Scaffolding #1 located at the southside of the structure under construction. b) Scaffolding #2 located at the eastside of the structure under construction.
Recent events (2)
- — I (S) $3000
- — Z (S) $3108
1926.451 H02 II
- Issued
- Penalty
- Initial $3108.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below. On or about February 8, 2022, at this work place, employees conducted framing operations from scaffolding more than 10 feet above a lower level and toeboards were not erected along the edge of the platform. a) Scaffolding #1 located at the southside of the structure under construction. b) Scaffolding#2 located at the eastside of the structure under construction.
Recent events (2)
- — I (S) $0
- — Z (S) $3108
1926.451 F03
- Issued
- Penalty
- Initial $3108.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. On or about February 8, 2022, at this work place, the competent person did not inspect the workplace scaffolding for visible defects which could affect the scaffolding structural integrity before each work shift while employees conducted framing operations from scaffolding more than 10 feet above a lower level. a) Scaffolding #1 located at the southside of the structure under construction. b) Scaffolding #2 located at the eastside of the structure under construction.
Recent events (2)
- — I (S) $3000
- — Z (S) $3108
1926.451 G01 VII
- Issued
- Penalty
- Initial $3108.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. On or about February 8, 2022, at this work place, employees conducted framing operations from scaffolding more than 10 feet above a lower level and were not protected from falls by the use of personal fall arrest systems or a guardrail system. a) Scaffolding #1 located at the southside of the structure under construction. b) Scaffolding #2 located at the eastside of the structure under construction.
Recent events (2)
- — I (S) $0
- — Z (S) $3108
More inspections in this industry (NAICS 236115)
REDDING, CA—2026-07-10
R&A RESOURCES, INC.
FRANCESTOWN, NH—2026-07-10
JM BUILDERS LLC
SAN JOSE, CA—2026-07-09
WALT OXLEY ENTERPRISES, INC.
BATAVIA, OH—2026-07-09
FISCHER SINGLE FAMILY HOMES IV, LLC
SARATOGA SPRINGS, UT—2026-07-09
JESSI CONSTRUCTION & PAINTING LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345809214.