CHIPPEWA FALLS, WI —
OSHA Inspection: MARKQUART RV - HALLIE, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MARKQUART RV - HALLIE, LLC in 11720 22ND AVENUE, CHIPPEWA FALLS, WI 54729 (NAICS 441210). OSHA activity number 345809511.
Where did this inspection happen?
- Establishment
- MARKQUART RV - HALLIE, LLC
- Site address
- 11720 22ND AVENUE
- City
- CHIPPEWA FALLS
- State
- WI
- ZIP
- 54729
- Mailing
- 11720 22ND AVENUE, CHIPPEWA FALLS, WI 54729
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441210
- Employees
- 30
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.106 D03 II A
- Issued
- Abate by
- Penalty
- Initial $5801.00 · Current $3481.00 Reduced
General-duty citation text
29 CFR 1910.106(d)(3)(ii)(a): Metal storage cabinets construction. The bottom, top, door, and sides of cabinet were not at least No. 18 gage sheet iron and double walled with 1 1/2 - inch air space. Joints were not riveted, welded or made tight by some equally effective means. The door was not provided with a three-point lock, and the door sill was not raised at least 2 inches above the bottom of the cabinet. (a) In the west service bay; the employer was using an improperly constructed metal cabinet to store flammable liquids used in the work area.
Recent events (2)
- — I (S) $3480.6
- — Z (S) $5801
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $4351.00 · Current $2611.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) In the east service bay; the employer did not ensure an eyewash station was immediately available where injurious corrosive liquids are used for cleaning campers.
Recent events (2)
- — I (S) $2610.6
- — Z (S) $4351
1910.178 L01 II
- Issued
- Abate by
- Penalty
- Initial $7252.00 · Current $4351.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck: (a) At the service facility; the employer did not ensure their forklift operators completed the required training process prior to assigning the operators tasks using the forklift.
Recent events (2)
- — I (S) $4351.2
- — Z (S) $7252
1910.215 A02
- Issued
- Abate by
- Penalty
- Initial $7252.00 · Current $4351.00 Reduced
General-duty citation text
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: (a) In the west service bay; the employer did not ensure a Black & Decker bench grinder had all the required guards installed.
Recent events (2)
- — I (S) $4351.2
- — Z (S) $7252
1910.215 A04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) In the west service bay; the employer did not ensure the Black & Decker bench grinder left wheel work rest was adjusted within one eighth of an inch to the grinding wheel surface.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 B09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) In the west service bay; the employer did not ensure the Black & Decker bench grinder had adjustable tongues installed and adjusted within one fourth of an inch to the grinding wheel surface.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Penalty
- Initial $3698.00 · Current $2219.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) In the show room; three outlet boxes had broken or missing faceplates.
Recent events (2)
- — I (S) $2218.8
- — Z (S) $3698
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $5801.00 · Current $3481.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program that included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (a) Throughout facility; the employer did not have an established hazard communication program to address hazards associated with the chemicals used in the service and maintenance areas.
Recent events (2)
- — I (S) $3480.6
- — Z (S) $5801
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a safety data sheet in the workplace for each hazardous chemical which they use: (a) Throughout facility; the employer did not provide safety data sheets for the chemicals used in the service and maintenance areas.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Throughout facility; the employer did not provide employees with training on hazardous chemicals used during RV and camper servicing and maintenance.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) In the east service bay; the employer did not ensure circuit breaker #14, located in the circuit breaker panel, was labelled to indicate its purpose.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 441210)
CLIFTON PARK, NY—2026-06-11
MEYER'S RV OF ALBANY, INC.
LAS VEGAS, NV—2026-06-10
FUN TOWN RV LAS VEGAS LLC
IRONWOOD, MI—2026-05-27
NORTHLAND LAWN & SPORT INC DBA NORTHLAND MOTORSPORTS
BENTON, AR—2026-05-12
CAMPING WORLD RV SALES, LLC
JOHNSTOWN, CO—2026-04-10
CAMPERS INN RV OF JOHNSTOWN, INC
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345809511.