Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: METSCH REFRACTORIES INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of METSCH REFRACTORIES INC in 12413 OHIO RIVER BLVD, CHESTER, WV 26034 (NAICS 212325). OSHA activity number 345815260.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Metsch Refractories INC — free Get an email when a new federal OSHA severe-injury report for Metsch Refractories INC is published. One employer, no account, unsubscribe in one click.
Site address
12413 OHIO RIVER BLVD
City
CHESTER
State
WV
ZIP
26034
Mailing
PO BOX 268, CHESTER, WV 26034
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
212325
Employees
43
Ownership type
A

6 citations on file for this inspection.

1910.23 B08

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Apr 12, 2022
Abate by
May 6, 2022
Penalty
Initial $4,351 · Current $0 Reduced
29 CFR  1910.23(b)(8): The employer did not ensure that ladders are used only for the purposes for which they were designed.  a) Air Compressor Room Roof: On February 28, 2022, and times prior, employees were exposed to falls up to 8 feet while using an a-frame ladder as an extension ladder to access the air compressor room roof to blow out filters.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4351

1910.23 C11

Deleted Serious Gravity 1 2 instances 1 exposed
Issued
Apr 12, 2022
Abate by
May 6, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.23(c)(11): The employer did not ensure that portable ladders used to gain access to an upper landing surface that have side rails that extend at least 3 feet (0.9 m) above the upper landing surface.  a) Air Compressor Room: On or about February 23, 2022, and times prior an employee used an 8 foot step ladder to gain access to the roof of the air compressor room to blow out the filter.   The employee is exposed to a fall hazard of 8 feet roof to floor while using the ladder to climb onto or off of the roof.  b) Dryer Room: On or about February 23, 2022, and times prior an employee used an 8 foot ladder to gain access to the roof of the dryer room to troubleshoot a problem on the furnace. The employee is exposed to a fall hazard of 8 feet roof to floor while using the ladder to climb onto or off of the roof.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.28 B01 I

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Apr 12, 2022
Abate by
May 27, 2022
Penalty
Initial $4,351 · Current $0 Reduced
29 CFR  1910.28(b)(1)(i):  Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):  a) Air compressor Room: On or about February 23, 2022, and times prior, an employee went onto the roof of the air compressor room to blow out the filter.  The roof is approximately 8 feet above ground and the employee was not provided with a fall protection system such as guard rails or personal fall arrest.  b) Kiln: On or about February 23, 2022, and times prior, an employee stood on a platform at the top edge of the kiln to grease a pulley.  The kiln top is approximately 6 feet above ground and the employee was not provided with a fall protection system such as guard rails or personal fall arrest.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4351

1910.147 C07 I A

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 12, 2022
Penalty
Initial $4,351 · Current $4,000 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:  a) Metsch Refractories, Inc; On or about February 23, 2022, and times prior,  an employee changed the  belt on a drill press, the hoses on a hydraulic press and performed dye changes on the press. The employee is identified as an authorized employee for LOTO but has not been trained as either an authorized or affected employee in hazardous energy control.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $4351

1910.147 C06 I

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 12, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) Metsch Refractories, Inc; On or about February 23, 2022, and times prior, employees perform servicing and maintenance activities such as replacing belts on drill presses, cleaning out mixers, and changing dyes on hydraulic presses.  The employer did not perform annual periodic inspections of the energy control program to ensure the requirements of the energy control standards are met.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 12, 2022
Abate by
Apr 22, 2022
Penalty
Initial $5,801 · Current $5,400 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Jet Drill Press: On or about November 2, 2021, and times prior, an employee used a Jet drill press to drill holes in product realization.  The rotating drill bit was not equipped with a guard to prevent employee exposure to flying chips and rotating parts.    b) Finishing Area Pour cup Machine: On or about March 2, 2022, and times prior, employees used a pour cup machine to knock off burrs on products.  The machine is equipped with a guard however the guard is not used on all products to prevent employee exposure to rotating parts.
Recent events (2)
  • — I (S) $5400
  • — Z (S) $5801

View Metsch Refractories INC's full OSHA safety record →