CHESTER, WV —
OSHA Inspection: METSCH REFRACTORIES INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of METSCH REFRACTORIES INC in 12413 OHIO RIVER BLVD, CHESTER, WV 26034 (NAICS 212325). OSHA activity number 345815260.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- METSCH REFRACTORIES INC
- Site address
- 12413 OHIO RIVER BLVD
- City
- CHESTER
- State
- WV
- ZIP
- 26034
- Mailing
- PO BOX 268, CHESTER, WV 26034
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 212325
- Employees
- 43
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.23 B08
- Issued
- Apr 12, 2022
- Abate by
- May 6, 2022
- Penalty
- Initial $4,351 · Current $0 Reduced
General-duty citation text
29 CFR 1910.23(b)(8): The employer did not ensure that ladders are used only for the purposes for which they were designed. a) Air Compressor Room Roof: On February 28, 2022, and times prior, employees were exposed to falls up to 8 feet while using an a-frame ladder as an extension ladder to access the air compressor room roof to blow out filters.
Recent events (2)
- — I (S) $0
- — Z (S) $4351
1910.23 C11
- Issued
- Apr 12, 2022
- Abate by
- May 6, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(c)(11): The employer did not ensure that portable ladders used to gain access to an upper landing surface that have side rails that extend at least 3 feet (0.9 m) above the upper landing surface. a) Air Compressor Room: On or about February 23, 2022, and times prior an employee used an 8 foot step ladder to gain access to the roof of the air compressor room to blow out the filter. The employee is exposed to a fall hazard of 8 feet roof to floor while using the ladder to climb onto or off of the roof. b) Dryer Room: On or about February 23, 2022, and times prior an employee used an 8 foot ladder to gain access to the roof of the dryer room to troubleshoot a problem on the furnace. The employee is exposed to a fall hazard of 8 feet roof to floor while using the ladder to climb onto or off of the roof.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.28 B01 I
- Issued
- Apr 12, 2022
- Abate by
- May 27, 2022
- Penalty
- Initial $4,351 · Current $0 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): a) Air compressor Room: On or about February 23, 2022, and times prior, an employee went onto the roof of the air compressor room to blow out the filter. The roof is approximately 8 feet above ground and the employee was not provided with a fall protection system such as guard rails or personal fall arrest. b) Kiln: On or about February 23, 2022, and times prior, an employee stood on a platform at the top edge of the kiln to grease a pulley. The kiln top is approximately 6 feet above ground and the employee was not provided with a fall protection system such as guard rails or personal fall arrest.
Recent events (2)
- — I (S) $0
- — Z (S) $4351
1910.147 C07 I A
- Issued
- Apr 12, 2022
- Penalty
- Initial $4,351 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: a) Metsch Refractories, Inc; On or about February 23, 2022, and times prior, an employee changed the belt on a drill press, the hoses on a hydraulic press and performed dye changes on the press. The employee is identified as an authorized employee for LOTO but has not been trained as either an authorized or affected employee in hazardous energy control.
Recent events (2)
- — I (S) $4000
- — Z (S) $4351
1910.147 C06 I
- Issued
- Apr 12, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Metsch Refractories, Inc; On or about February 23, 2022, and times prior, employees perform servicing and maintenance activities such as replacing belts on drill presses, cleaning out mixers, and changing dyes on hydraulic presses. The employer did not perform annual periodic inspections of the energy control program to ensure the requirements of the energy control standards are met.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Apr 12, 2022
- Abate by
- Apr 22, 2022
- Penalty
- Initial $5,801 · Current $5,400 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Jet Drill Press: On or about November 2, 2021, and times prior, an employee used a Jet drill press to drill holes in product realization. The rotating drill bit was not equipped with a guard to prevent employee exposure to flying chips and rotating parts. b) Finishing Area Pour cup Machine: On or about March 2, 2022, and times prior, employees used a pour cup machine to knock off burrs on products. The machine is equipped with a guard however the guard is not used on all products to prevent employee exposure to rotating parts.
Recent events (2)
- — I (S) $5400
- — Z (S) $5801
More inspections at Metsch Refractories INC