OSHA Inspection: NAPA AUTO PARTS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NAPA AUTO PARTS in 722 WETHERSFIELD AVENUE, HARTFORD, CT 06114 (NAICS 441310). OSHA activity number 345815435.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Napa Auto Parts — free Get an email when a new federal OSHA severe-injury report for Napa Auto Parts is published. One employer, no account, unsubscribe in one click.
Establishment
NAPA AUTO PARTS
Site address
722 WETHERSFIELD AVENUE
City
HARTFORD
State
CT
ZIP
06114
Mailing
722 WETHERSFIELD AVENUE, HARTFORD, CT 06114
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441310
Employees
15
Ownership type
A

5 citations on file for this inspection.

1910.37 A03

Serious Gravity 1 2 instances 5 exposed
Issued
Jul 8, 2022
Abate by
Aug 24, 2022
Penalty
Initial $4,351 · Current $3,384 Reduced
29 CFR  1910.37(a)(3): Exit routes were not kept free and unobstructed.  Materials or equipment were placed, either permanently or temporarily, within the exit route:  On or about March 02, 2022, at 722 Wethersfield Avenue, Hartford, CT; exit door located on the west wall of warehouse: The employer did not keep exit route unblocked and free of  merchandise.  Exit routes were obstructed by the storage of a plastic bucket and boxes of new merchandise on either side of the emergency egress route.
Recent events (2)
  • — I (S) $3384
  • — Z (S) $4351

1910.37 B05

Serious Gravity 1 1 instance 5 exposed
Issued
Jul 8, 2022
Abate by
Aug 24, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use.  On or about March 02, 2022, at 722 Wethersfield Avenue, Hartford, CT; Door located on the west wall of warehouse: The employer did not identify a doorway or passage along an exit access as Not an Exit, exposing employees to delayed egress in the event of an emergency.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 II

Serious Gravity 1 3 instances 5 exposed
Issued
Jul 8, 2022
Abate by
Aug 24, 2022
Penalty
Initial $4,351 · Current $3,384 Reduced
29 CFR  1910.303(g)(1)(ii):The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:   On or about March 02, 2022 at 722 Wethersfield Avenue, Hartford, CT; Electrical panels located on the east wall of the warehouse:  Employer did not allow a clear working space clearances for electrical panels.  The access to the  electric breaker box panels were not provided.  The working space for electric breaker box panels must be kept clear at all times for operation and for maintenance personnel. There were three (3) instances of electrical panels blocked as follow:  Picture DSCN 2087 shows blocked electrical panels located on the east wall of the warehouse.    Picture DSCN 2089 shows blocked electrical panels, about 50 feet south DSCN2087, blocked by a shelves structure.  Picture DSCN 2094-2096 shows the west wall of the closed storage building (cinder blocked structure) with a High Voltage - Danger sign on the door.
Recent events (2)
  • — I (S) $3384
  • — Z (S) $4351

1910.305 B02 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jul 8, 2022
Abate by
Aug 24, 2022
Penalty
Initial $5,801 · Current $0 Reduced
29 CFR  1910.305(b)(2)(i):Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:   On or about March 02-2022, at the 722 Wethersfield Avenue, Hartford, CT; Electrical connection switch box, located on the south wall of warehouse:  The electrical connection switch box, located on the south wall of warehouse did not have an electrical faceplate to cover over electrical connection. Employees were exposed  to electric shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5801

1910.176 B

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 8, 2022
Abate by
Aug 24, 2022
Penalty
Initial $5,801 · Current $3,384 Reduced
29 CFR  1910.176(b):Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:  On or about March 02, 2022 at 722 Wethersfield Avenue, Hartford, CT; within warehouse area: The employer did not secure materials  to prevent any object , boxes, or pallets from falling out of the rack.  The employer stored boxes, bags, containers, and bundles of various sizes in tiers on metal shelves; but not stacked, blocked, interlocked and limited in height.  The stored products were not stable and secured against sliding or collapse.
Recent events (2)
  • — I (S) $3384
  • — Z (S) $5801

View Napa Auto Parts's full OSHA safety record →