Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WAND NEWCO 3, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of WAND NEWCO 3, INC. in 211 DEKALB INDUSTRIAL WAY, DECATUR, GA 30030 (NAICS 811121). OSHA activity number 345818645.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wand Newco 3, INC. — free Get an email when a new federal OSHA severe-injury report for Wand Newco 3, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
WAND NEWCO 3, INC.
Site address
211 DEKALB INDUSTRIAL WAY
City
DECATUR
State
GA
ZIP
30030
Mailing
2941 LAKE VISTA DR, LEWISVILLE, TX 75067
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
10
Ownership type
A

4 citations on file for this inspection.

1910.107 C06

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Jun 24, 2022
Abate by
Jul 21, 2022
Penalty
Initial $5,283 · Current $0 Reduced
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:  Painting area located at 211 Dekalb Industrial Way, Decatur, GA; On or about March 3, 2022, employees are required to prime cars and conduct paining in the shop area outside of the spray booths.  Electrical equipment such as but is not limited to extension cords and electrical outlets are located in the shop area. The electrical equipment was not approved for the location, exposing employees to a fire hazard.
Recent events (3)
  • — F (S) $0
  • — C (S) $5283
  • — Z (S) $5283

1910.134 F02

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Jun 24, 2022
Penalty
Initial $5,283 · Current $3,522 Reduced
29 CFR  1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:   (a) Painting area located at 211 Dekalb Industrial Way, Decatur, GA; on or about March 3, 2022, an employee wearing a 3M half mask respirator for prepping and mixing paints was not fit tested.
Recent events (3)
  • — F (O) $3522
  • — C (S) $5283
  • — Z (S) $5283

1910.134 G01 I A

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Jun 24, 2022
Abate by
Jul 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:   (a) Painting area located at 211 Dekalb Industrial Way, Decatur, GA; on or about March 3, 2022, an employee wearing a 3M half mask respirator for prepping cars and the employer did not ensure that the employee was cleaned shaven.
Recent events (3)
  • — R (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.107 B09

Other-than-serious 1 instance 1 exposed
Issued
Jun 24, 2022
Abate by
Jul 21, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction:  (a)  Painting area located at 211 Dekalb Industrial Way, Decatur, GA; On or about March 3, 2022, spray booths were so installed that all portions were not readily accessible for cleaning.  A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction on the exterior of the spray booths.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Wand Newco 3, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345818645.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.