Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MOUNTAIN STANDARD CONTRACTORS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MOUNTAIN STANDARD CONTRACTORS INC. in 12792 BEND COURT, FIRESTONE, CO 80504 (NAICS 238170). OSHA activity number 345823181.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mountain Standard Contractors INC. — free Get an email when a new federal OSHA severe-injury report for Mountain Standard Contractors INC. is published. One employer, no account, unsubscribe in one click.
Site address
12792 BEND COURT
City
FIRESTONE
State
CO
ZIP
80504
Mailing
1151 EAGLE DRIVE UNIT 357, LOVELAND, CO 80537
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
10
Ownership type
A

3 citations on file for this inspection.

1926.451 C02

Serious Gravity 10 3 instances 2 exposed
Issued
Mar 31, 2022
Penalty
Initial $4,351 · Current $2,611 Reduced
29 CFR  1926.451(c)(2):Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:  (a) Location - 12792 Bend Court, Firestone, CO  On or about 02/04/2022, employees were on a pump jack scaffolding that was not on mudsills exposing the employees to a fall hazard.
Recent events (2)
  • — I (S) $2610.6
  • — Z (S) $4351

1926.451 G04 I

Serious Gravity 10 4 instances 1 exposed
Issued
Mar 31, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.451(g)(4)(i):Guardrail systems were not installed along all open sides and ends of platforms.  (a) Location - 12792 Bend Court, firestone, CO  On or about 02/04/2022, employee was exposed to fall hazard while working on a pump jack scaffolding with no end rails and mid rails.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 J02

Serious Gravity 10 3 instances 1 exposed
Issued
Mar 31, 2022
Abate by
Jun 8, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.452(j)(2):Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.  (a) Location - 12792 Bend Court, Firestone, CO  On ro about 02/04/2022, employee were exposed to fall hazards when working on a pump jack scaffolding with on one rigid triangular brace in place on each pole creating an unstable platform.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Mountain Standard Contractors INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345823181.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.