CUMMING, GA —
OSHA Inspection: ACCUFAB, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ACCUFAB, INC. in 1370 WEBER INDUSTRIAL DR., CUMMING, GA 30041 (NAICS 332322). OSHA activity number 345824908.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACCUFAB, INC.
- Site address
- 1370 WEBER INDUSTRIAL DR.
- City
- CUMMING
- State
- GA
- ZIP
- 30041
- Mailing
- 1370 WEBER INDUSTRIAL DR., CUMMING, GA 30041
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 56
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II
- Issued
- Aug 30, 2022
- Abate by
- Oct 18, 2022
- Penalty
- Initial $6,164 · Current $6,164
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) Plant; on or about March 9, 2022 and at times prior to, employees were exposed to hazardous electrical energy, compressed gas, and hydraulic energy, in that the employer failed to include all required steps and information in the specific lockout/tagout procedures, such us but not limited to scope and purpose, energy types and magnitudes, methods of energy control, and locking hardware.
Recent events (1)
- — Z (S) $6164
1910.178 Q06
- Issued
- Aug 30, 2022
- Abate by
- Oct 18, 2022
- Penalty
- Initial $6,164 · Current $6,164
General-duty citation text
29 CFR 1910.178(q)(6): Industrial trucks were altered so that the relative positions of the various parts were different from what they were when originally received from the manufacturer and were altered either by the addition of extra parts not provided by the manufacturer or by the elimination of any parts. a) Plant; on or about March 9, 2022 and at times prior to, employees were exposed to struck-by and falling-object hazards, in that the employer operated forklifts without the front rack designed by the manufacturer to protect hydraulic hoses from damage, and to prevent hose failure and the sudden drop of the forks.
Recent events (1)
- — Z (S) $6164
1910.303 B02
- Issued
- Aug 30, 2022
- Abate by
- Oct 18, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Plant; on or about March 9, 2022 and at times prior to, employees were exposed to electrical hazards, in that the employer powered portable equipment around plant machinery with relocatable power taps (power strips) which were not installed according to the instructions in the listing or labeling.
Recent events (1)
- — Z (O) $0
More inspections at Accufab, INC.
View Accufab, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345824908.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.