Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STARKE MACHINE CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STARKE MACHINE CO. in 2109 BRENNAN AVENUE, FORT WORTH, TX 76106 (NAICS 332710). OSHA activity number 345832778.

Watch Starke Machine CO. — free Get an email when a new federal OSHA severe-injury report for Starke Machine CO. is published. One employer, no account, unsubscribe in one click.
Establishment
STARKE MACHINE CO.
Site address
2109 BRENNAN AVENUE
City
FORT WORTH
State
TX
ZIP
76106
Mailing
2109 BRENNAN AVENUE, FORT WORTH, TX 76106
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
39
Ownership type
A

4 citations on file for this inspection.

1910.37 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4351.00 · Current $2611.00 Reduced
29 CFR  1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit".   In the shipping room, on March 11, 2022, and times prior thereto, the employer did not ensure the exit door was equipped with an "EXIT" sign exposing employees to entrapment hazards.
Recent events (2)
  • — I (S) $2610.6
  • — Z (S) $4351

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $4931.00 · Current $2959.00 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   In the machine shop area, the employer did not ensure the SL-35 SMEC Samsung machine interlock was in operation exposing employees to caught-in hazards.
Recent events (2)
  • — I (S) $2958.6
  • — Z (S) $4931

1910.303 B02

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $692.00 · Current $415.00 Reduced
29 CFR  1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing and labeling.   In the marking department, on March 11, 2022, and times prior thereto, power tap was plugged into another power tap not required by UL Directory that contains instructions that require UL-listed RPTs to be directly connected to a permanently installed branch circuit receptacle and not to be series-connected to other RPTs that is not required by the listing and labeling.
Recent events (2)
  • — I (O) $415.2
  • — Z (O) $692

1910.305 G01 IV

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $692.00 · Current $415.00 Reduced
29 CFR  1910.305(g)(1)(iv): Flexible cords and cables were used for purposes prohibited by subparagraphs (a) through (e) of this paragraph:   In the mill department, on March 11, 2022, and times prior thereto, an extension cord was wrapped around a metal conduit, was used as permanent wiring to energize a computer and a table light,  exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $415.2
  • — Z (O) $692