Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LHM COLLISION CSCO, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of LHM COLLISION CSCO, LLC in 5597 N. ACADEMY BLVD., COLORADO SPRINGS, CO 80918 (NAICS 811121). OSHA activity number 345833503.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch LHM Collision Csco, LLC — free Get an email when a new federal OSHA severe-injury report for LHM Collision Csco, LLC is published. One employer, no account, unsubscribe in one click.
Site address
5597 N. ACADEMY BLVD.
City
COLORADO SPRINGS
State
CO
ZIP
80918
Mailing
5597 N. ACADEMY BLVD., COLORADO SPRINGS, CO 80918
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811121
Employees
17
Ownership type
A

2 citations on file for this inspection.

1910.134 G01 I A

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 1, 2022
Abate by
Apr 13, 2022
Penalty
Initial $2,486 · Current $2,486
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:  (a) On or about  March 14, 2022, and at times prior, an employees who was required to wear tight-fitting respirator in the collision area had facial hair between the skin and seal of the tight fitting respirator.
Recent events (1)
  • — Z (S) $2486

1910.303 G01

Other-than-serious 1 instance 17 exposed
Issued
Apr 1, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a)  On or about March 14, 2022, and at times prior, the employer did not maintain a clear distance of three feet in front of the circuit breaker panels order to permit safe operation and maintenance of equipment.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345833503.