Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CINEMATION DESIGN, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CINEMATION DESIGN, LLC in 11983 CLEVELAND GIBBS ROAD, ROANOKE, TX 76262 (NAICS 541410). OSHA activity number 345838296.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cinemation Design, LLC — free Get an email when a new federal OSHA severe-injury report for Cinemation Design, LLC is published. One employer, no account, unsubscribe in one click.
Site address
11983 CLEVELAND GIBBS ROAD
City
ROANOKE
State
TX
ZIP
76262
Mailing
11983 CLEVELAND GIBBS ROAD, ROANOKE, TX 76262
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541410
Employees
12
Ownership type
A

7 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 1 instance 12 exposed
Issued
Mar 28, 2022
Abate by
Apr 25, 2022
Penalty
Initial $3,315 · Current $1,989 Reduced
29 CFR  1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).  On or about March 15, 2022, and at times prior thereto, the employer did not ensure employees/workers were trained, evaluated  and competent to operate a powered industrial truck, exposing them to struck-by, roll-over and ejection hazards.
Recent events (2)
  • — I (S) $1989
  • — Z (S) $3315

1910.253 B04 I

Serious Gravity 1 1 instance 12 exposed
Issued
Mar 28, 2022
Abate by
Apr 25, 2022
Penalty
Initial $2,486 · Current $1,492 Reduced
29 CFR  1910.253(b)(4)(i): Oxygen cylinders shall not be stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near any other substance likely to cause or accelerate fire; or in an acetylene generator compartment.  On or about March 15, 2022, at at times prior thereto, the employer did not ensure oxygen and acetylene cylinders in the shop area were stored and secured in a partition separating the cylinders which exposed workers/employees to combustible and fire hazards.
Recent events (2)
  • — I (S) $1491.6
  • — Z (S) $2486

1910.254 D09 I

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 28, 2022
Abate by
Apr 25, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.254(d)(9)(i): The operator did not report any equipment defect or safety hazard to his supervisor and the use of the equipment will be discontinued until its safety has been assured. Repairs was not made by qualified personnel.  On or about March 15, 2022 and at times prior thereto,  the employer did not ensure the Millermatic 350P Aluminum welding machine was taken out of service when wires were pulled away and were exposed on the welder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 3 instances 12 exposed
Issued
Mar 28, 2022
Penalty
Initial $2,113 · Current $1,268 Reduced
29 CFR  1910.303(b)(2):Installation and use. Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling.  On or about March 15, 2022, and at times prior thereto, employees were not protected from electrical shock hazards where metal electrical gang/ junction boxes designed for mounting were used as;  a) a portable extension cord  to operate the the pipe bending machine,  b) a portable extension cord to operate the miller welders in the shop, and  c) a portable extension cord on job sites to work on outside projects for the company.
Recent events (2)
  • — I (S) $1267.8
  • — Z (S) $2113

1910.305 G02 III

Serious Gravity 5 4 instances 12 exposed
Issued
Mar 28, 2022
Abate by
Apr 25, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(g)(2)(iii):Flexible cords and cables was not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.   On or about March 15, 2022, and at times prior thereto, employees were not protected from electrical shock and fire hazards where electrical cord outer sheathing was pulled away exposing conductors and not having fittings or devices that would prevent direct pull and abrasion to the wires;  a)  in the shop welding area, the Millermatic 350p plug/cable was not equipped with strain relief,  b)  in the shop next to the welding area the pedal wiring on pipe bender  was not equipped with strain relief,   c)  the wiring going into the pipe bender from the foot pedal was not equipped with strain relief, and   d) the extension cord used for outside projects was not equipped with strain relief.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 1 4 instances 12 exposed
Issued
Mar 28, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(i):Portable cord and plug connected equipment and flexible cord sets (extension cords) was not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord and plug connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.  On or about March 15, 2022, and at times prior thereto, the employer did not ensure each portable cord and plug connected equipment was visually inspected before use on any shift for external defects.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.29 A

Other-than-serious 1 instance 12 exposed
Issued
Mar 28, 2022
Abate by
Apr 25, 2022
Penalty
Initial $829 · Current $497 Reduced
29 CFR 1904.29(a): The employer did not use an OSHA 300, 301 and 300A Form or equivalent.  On or about March 15, 2022, and at times prior thereto, the employer did not maintain or have available OSHA 300, 301, 300A or equivalent forms for recording injuries and illnesses of employee's located at Cinemation Design Inc.
Recent events (2)
  • — I (O) $497.4
  • — Z (O) $829

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345838296.