HUDSON, WI —
OSHA Inspection: FERYASA CONSTRUCTION L.L.C.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FERYASA CONSTRUCTION L.L.C. in 741 MAGOO ROAD, HUDSON, WI 54016 (NAICS 238130). OSHA activity number 345838932.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FERYASA CONSTRUCTION L.L.C.
- Site address
- 741 MAGOO ROAD
- City
- HUDSON
- State
- WI
- ZIP
- 54016
- Mailing
- P. O. BOX 496, RIVER FALLS, WI 54022
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.405 G02 III
- Issued
- Apr 21, 2022
- Penalty
- Initial $1,865 · Current $1,865
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap: (a) West end interior, ground level; Two 16 AWG flexible extension cords were spliced together near the male plug-end to form one cord and was used to supply power to portable electric equipment.
Recent events (1)
- — Z (S) $1865
1926.405 G02 IV
- Issued
- Apr 21, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a) West end interior, second level; The outer jacket of the power cord for a Dewalt brand Model DW303 reciprocating saw was damaged and open at the base of the strain relief boot, rendering the strain relief ineffective and causing pull to be transmitted to the terminal screws.
Recent events (1)
- — Z (S) $0
1926.416 E01
- Issued
- Apr 21, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: (a) West end interior, ground level; A spliced 16 AWG flexible extension cord used to supply power to portable electric equipment had damage to the outer jacket in several areas, exposing inner wires. (b) West end interior, second level; The outer jacket of the power cord for a Dewalt brand Model DW303 reciprocating saw was damaged and open at the base of the strain relief boot, exposing frayed inner wires.
Recent events (1)
- — Z (S) $0
1926.501 B13
- Issued
- Apr 21, 2022
- Abate by
- May 5, 2022
- Penalty
- Initial $4,351 · Current $4,351
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Roof structure, various locations; Fall protection systems were not in place while employees performed framing work from top chords and/or webs of roof trusses at approximate heights ranging between 7-feet, 6 inches to 18-feet, 10 inches above lower levels. (b) West end interior, second level; Employees were performing work near interior unguarded floor openings with edges approximately 10.5 feet above lower levels without the use of fall protection.
Recent events (1)
- — Z (S) $4351
1926.1053 B13
- Issued
- Apr 21, 2022
- Penalty
- Initial $3,108 · Current $3,108
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: (a) West end interior, intermediate stairway landing; The top step of a Gorilla brand 18-foot aluminum multi-position ladder configured as a stepladder was used as a step by employees while accessing and egressing the second level. (b) East end interior, second level; The top cap of a Werner brand 6-foot fiberglass stepladder was used as a step by employees while accessing and egressing the roof structure.
Recent events (1)
- — Z (S) $3108
More inspections at Feryasa Construction L.L.C.