Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WELLBORN CABINET, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of WELLBORN CABINET, INC. in 38669 HIGHWAY 77, ASHLAND, AL 36251 (NAICS 337110). OSHA activity number 345839146.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wellborn Cabinet, INC. — free Get an email when a new federal OSHA severe-injury report for Wellborn Cabinet, INC. is published. One employer, no account, unsubscribe in one click.
Site address
38669 HIGHWAY 77
City
ASHLAND
State
AL
ZIP
36251
Mailing
38669 HIGHWAY 77, ASHLAND, AL 36251
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
1200
Ownership type
A

8 citations on file for this inspection.

1910.23 B08

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Sep 15, 2022
Abate by
Sep 26, 2022
Penalty
Initial $14,502 · Current $0 Reduced
29 CFR  1910.23(b)(8): The employer did not ensure that ladders are used only for the purposes for which they were designed:  On or about 03/16/22 and times prior,  employees used an A-frame ladder to access the top of a spray booth by side-stepping:  (a)	On or about 03/16/22, and times prior,  at 38669 Highway 77, Ashland, AL  36251, in the paint room, at paint booth 3015, an employee was exposed to a fall hazard when a portable ladder was used to access the top of the spray paint booth.
Recent events (3)
  • — F (S) $0
  • — C (S) $14502
  • — Z (S) $14502

1910.28 B01 I

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2022
Abate by
Aug 28, 2023
Penalty
Initial $14,502 · Current $14,502
29 CFR 1910.28(b)(1)(i):  Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):  (a) On or about 3/16/2022, and at times prior, at 38669 Highway 77, Ashland, AL 36251, in the paint room, at paint booth 3015, employees installing a light fixture for the paint booth were exposed to a fall hazard of 7 feet 2 inches.
Recent events (3)
  • — F (O) $14502
  • — C (S) $14502
  • — Z (S) $14502

1910.133 A01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Sep 15, 2022
Abate by
Sep 27, 2022
Penalty
Initial $13,674 · Current $0 Reduced
29 CFR  1910.133(a)(1):Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:   (a)  On or about 3/16/22, and at times prior, eye protection was not provided for employees performing spraying operations.
Recent events (3)
  • — F (S) $0
  • — C (S) $13674
  • — Z (S) $13674

1910.333 B02 II A

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2022
Abate by
Aug 28, 2023
Penalty
Initial $14,502 · Current $14,502
29 CFR  1910.333(b)(2)(ii)(A): Safe procedures for deenergizing circuits and equipment were not determined before circuits or equipment are deenergized:  (a) On or about 3/16/2022, and at times prior, at 38669 Highway 77, Ashland, AL 36251, in the paint room, at paint booth 3015 , employees were exposed to electrical hazards when installing LED starters and exposed to 277- volt electrical circuits without safe procedures.
Recent events (3)
  • — F (S) $14502
  • — C (S) $14502
  • — Z (S) $14502

1910.333 B02 III A

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2022
Abate by
Aug 28, 2023
Penalty
Initial $14,502 · Current $0 Reduced
29 CFR  1910.333(b)(2)(iii)(A): A lock and a tag were not placed on each disconnecting means used to deenergize circuits and equipment on which work was to be performed:  (a) On or about 3/16/2022, and at times prior, at 38669 Highway 77, Ashland, AL 36251, in the paint room, at paint booth 3015, employees were exposed to electrical hazards when a lock and tag were not utilized when work was performed.
Recent events (3)
  • — F (S) $0
  • — C (S) $14502
  • — Z (S) $14502

1910.333 B02 II B

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2022
Abate by
Aug 28, 2023
Penalty
Initial $14,502 · Current $0 Reduced
29 CFR  1910.333(b)(2)(ii)(B):  Control circuit devices, such as push buttons, selector switches, and interlocks, were used as the sole means for deenergizing circuits and equipment:  (a) On or about 3/16/2022, and at times prior, at 38669 Highway 77, Ashland, AL 36251, in the paint room, at paint booth 3015, employees installing light fixtures in the paint booth were exposed to electrical hazards when push buttons were utilized  to deenergize circuits and equipment.
Recent events (3)
  • — F (S) $0
  • — C (S) $14502
  • — Z (S) $14502

1910.333 B02 IV B

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2022
Abate by
Aug 28, 2023
Penalty
Initial $14,502 · Current $14,502
29 CFR  1910.333(b)(2)(iv)(B):Before circuits or equipment was worked as deenergized, a qualified person did not use test equipment to test the circuit elements and electrical parts of equipment to which employees would be exposed and did not verify that the circuit elements and equipment parts are deenergized:   (a) On or about 3/16/2022, and at times prior, at 38669 Highway 77, Ashland, AL 36251, in the paint room, at paint booth 3015, employees installing light fixtures in the paint booth were exposed to electrical hazards when the circuit elements and equipment parts were not verified to be deenergized.
Recent events (3)
  • — F (O) $14502
  • — C (S) $14502
  • — Z (S) $14502

1910.305 B01 II

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2022
Abate by
Aug 28, 2023
Penalty
Initial $14,502 · Current $14,502
29 CFR  1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a) On or about 3/16/2022, and at times prior, at 38669 Highway 77, Ashland, AL 36251, at Power  Panel 480/277 Volts for the paint booths, employees were exposed to electrical hazards when the unused opening at Position 16 (Glaze Room) was not covered.
Recent events (3)
  • — F (O) $14502
  • — C (S) $14502
  • — Z (S) $14502

View Wellborn Cabinet, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345839146.