Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WALKER COMMERCIAL INTERIORS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WALKER COMMERCIAL INTERIORS, LLC in 201 BISCAYNE BLVD, MIAMI, FL 33131 (NAICS 238310). OSHA activity number 345842447.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Walker Commercial Interiors, LLC — free Get an email when a new federal OSHA severe-injury report for Walker Commercial Interiors, LLC is published. One employer, no account, unsubscribe in one click.
Site address
201 BISCAYNE BLVD
City
MIAMI
State
FL
ZIP
33131
Mailing
3758 SW 30TH AVE, FORT LAUDERDALE, FL 33312
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
100
Ownership type
A

2 citations on file for this inspection.

1926.451 F03

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 15, 2022
Abate by
Jul 13, 2022
Penalty
Initial $8,702 · Current $6,091 Reduced
29 CFR  1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:  On or about March 18, 2022, at jobsite located at 201 Biscayne Blvd,  Miami, FL, 33131: an employee was exposed to a 5-foot fall hazard while performing drywall work from a mobile welded tubular scaffold with a defective locking mechanisms on  two of the casters.  IN THE ALTERNATIVE:  29 CFR  1926.452(w)(2): Scaffold casters and wheels were not locked with positive wheel and/or wheel and swivel locks, or equivalent means, to prevent movement of the scaffold while the scaffold was used in a stationary manner:  On or about March 18, 2022, at jobsite located at 201 Biscayne Blvd,  Miami, FL, 33131: an employee was exposed to a 5-foot fall hazard while performing drywall work from a mobile welded tubular scaffold without ensuring the casters were locked to prevent movement of the scaffold while the scaffold was being used.
Recent events (2)
  • — I (S) $6091.4
  • — Z (S) $8702

1926.452 W09

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 15, 2022
Abate by
Jul 13, 2022
Penalty
Initial $8,702 · Current $6,091 Reduced
29 CFR  1926.452(w)(9): Caster stems and wheel stems were not pinned or otherwise secured in scaffold legs or adjustment screws:  On or about March 18, 2022, at jobsite located at 201 Biscayne Blvd,  Miami, FL, 33131: an employee was exposed to a 5-foot fall hazard while performing form work from a mobile welded tubular scaffold in which the caster stems were installed with rebar tie wire and not pinned and secured in the scaffold's legs.
Recent events (2)
  • — I (S) $6091.4
  • — Z (S) $8702

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345842447.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.