Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DOLLAR GENERAL CORPORATION/DOLGENCORP, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DOLLAR GENERAL CORPORATION/DOLGENCORP, LLC in 103 SOUTH HIGHWAY 29, HOGANSVILLE, GA 30230 (NAICS 445120). OSHA activity number 345853154.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dollar General Corporation/Dolgencorp, LLC — free Get an email when a new federal OSHA severe-injury report for Dollar General Corporation/Dolgencorp, LLC is published. One employer, no account, unsubscribe in one click.
Site address
103 SOUTH HIGHWAY 29
City
HOGANSVILLE
State
GA
ZIP
30230
Mailing
100 MISSION RDG, GOODLETTSVILLE, TN 37072
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
445120
Employees
5
Ownership type
A

5 citations on file for this inspection.

1910.22 A01

Willful Gravity 5 1 instance 2 exposed
Issued
Aug 11, 2022
Abate by
Aug 30, 2022
Penalty
Initial $136,736 · Current $136,736
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.  a) The employer fails to ensure effective protection against struck-by, trip, and fire hazards as required by the standard, as demonstrated on or about March 23, 2022, at 103 South Highway 29 Hogansville, GA, when the receiving/storage room was not kept clean, sanitary, and orderly, preventing employees from moving product in and out of the receiving/storage room onto the sales floor and from delivery trucks. To abate this violation, the employer must ensure that the receiving/storage room is clean and organized.
Recent events (3)
  • — F (W) $136736
  • — C (W) $136736
  • — Z (W) $136736

1910.37 A03

Willful Gravity 5 1 instance 2 exposed
Issued
Aug 11, 2022
Abate by
Aug 30, 2022
Penalty
Initial $136,736 · Current $136,736
29 CFR  1910.37(a)(3):Exit route(s) were not kept free and unobstructed:  a) The employer fails to ensure effective measures to prevent fire and entrapment hazards as demonstrated on or about March 23, 2022 at 103 South Highway 29 Hogansville, GA, in the receiving/storage room, where employees work the merchandise. The far-left emergency exit door and the exit door between the receiving room and the main sales floor was obstructed by store merchandise, roll-tainers, and U-boats, impeding direct means of egress for employees in the event of an emergency. To abate this violation, the employer must ensure that all emergency exit routes are kept unobstructed and free from product to ensure a safe walkway for employees to exit the emergency exit door in case of an emergency.
Recent events (3)
  • — F (W) $136736
  • — C (W) $136736
  • — Z (W) $136736

1910.176 B

Willful Gravity 5 1 instance 2 exposed
Issued
Aug 11, 2022
Abate by
Aug 30, 2022
Penalty
Initial $136,736 · Current $136,736
29 CFR  1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:  a) The employer fails to ensure effective protection against struck-by hazards as required by the standard, as demonstrated on or about March 23, 2022, at 103 South Highway 29 Hogansville, Georgia, in the receiving/storage room, boxes and loose materials were stacked in a way that was unbalanced, unstable, unsecure which could not prevent the merchandise from falling onto or in the path of employees. Product was stacked at heights greater than 9 feet and leaning. To abate this violation, the employer must ensure that the receiving room has stable and secure material and product in that the material is stored in tiers that is stacked, blocked, interlocked, and limited to a height to prevent the product and material from sliding or collapsing onto employees when they try to remove or grab the material to restock the store.
Recent events (3)
  • — F (W) $136736
  • — C (W) $136736
  • — Z (W) $136736

1910.303 G01 II

Willful Gravity 5 1 instance 2 exposed
Issued
Aug 11, 2022
Abate by
Aug 30, 2022
Penalty
Initial $136,736 · Current $136,736
29 CFR  1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a) The employer fails to ensure effective measures to prevent slip/trip, struck-by, fire, and electrical hazards as demonstrated on or about March 23, 2022 at 103 South Highway 29 Hogansville, GA, in the receiving/storage room, boxes and loose merchandise were stored in front of the electrical panels, blocking access to the panels. To abate this hazard, the employer must ensure that the area in front of electrical panels is kept clear of merchandise, cardboard boxes, U-boats, plastic bins, and other items.
Recent events (3)
  • — F (W) $136736
  • — C (W) $136736
  • — Z (W) $136736

1910.305 G01 IV A

Deleted Repeat Gravity 5 1 instance 2 exposed
Issued
Aug 11, 2022
Penalty
Initial $91,157 · Current $0 Reduced
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Office to Break Room; On or about March 23, 2022 and at times prior, employees were exposed to fire hazards, in that a flexible cord from the store's office was used to power a refrigerator and microwave in the break room.   The Dolgencorp LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(g)(1)(iv)(A), which was contained in OSHA inspection number 1455672, citation number 2, item number 1 and was affirmed as a final order on 5/13/2020, with respect to a workplace located at 40976 AL 77 South, ASHLAND, AL 36251.  The Dollar General Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(g)(1)(iv)(A), which was contained in OSHA inspection number 1283802, citation number 1, item number 2 and was affirmed as a final order on 1/23/2018, with respect to a workplace located at 2222 Texoma Pkwy Sherman, TX 75090.
Recent events (3)
  • — F (R) $0
  • — C (R) $91157
  • — Z (R) $91157

View Dollar General Corporation/Dolgencorp, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345853154.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.