OSHA Inspection: BRESLER EITEL ART & FRAMING, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BRESLER EITEL ART & FRAMING, LLC in 525 WEST WALNUT STREET, MILWAUKEE, WI 53212 (NAICS 423220). OSHA activity number 345854053.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bresler Eitel ART & Framing, LLC for free Get an email when a new federal OSHA severe-injury report for Bresler Eitel ART & Framing, LLC is published. One employer, no account, unsubscribe in one click.
Site address
525 WEST WALNUT STREET
City
MILWAUKEE
State
WI
ZIP
53212
Mailing
525 W WALNUT STREET, MILWAUKEE, WI 53212
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423220
Employees
12
Ownership type
Private (A)

4 citations on file for this inspection.

1910.147 C01

Other-than-serious Gravity 5 1 instance 11 exposed
Issued
Sep 2, 2022
Abate by
Oct 14, 2022
Penalty
Initial $3,522 · Current $0 Reduced
29 CFR  1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  (a) On or about March 24, 2022, the employer did not establish a program consisting of energy control procedures, employee training and periodic inspections, to ensure that before any employee performs servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury.
Recent events (2)
  • · I (O) $0
  • · Z (S) $3522

1910.147 C04 I

Other-than-serious Gravity 5 1 instance 11 exposed
Issued
Sep 2, 2022
Abate by
Oct 14, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) On or about March 24, 2022, the employer did not ensure procedures were developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section, which  includes maintenance and servicing of saws and dust collection systems.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 18, 2022
Penalty
Initial $2,994 · Current $2,094 Reduced
29 CFR  1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  (a)  On or about March 24, 2022, employees were exposed to laceration and amputation hazards while working on and around the Menards 10" Table Saw (Model #5-1984 and Serial #10517). The employer did not ensure the point of operation was guarded.
Recent events (2)
  • · I (S) $2094
  • · Z (S) $2994

1910.37 B02

Other-than-serious 1 instance 8 exposed
Issued
Aug 18, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  (a)  On or about March 24, 2022, the exit sign on the exit door located on the eastern wall was not clearly visible, in-that the sign was not illuminated and the exit sign was broken out.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0