Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J&P MARINE CONSTRUCTION, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of J&P MARINE CONSTRUCTION, INC. in 3281 NORTH 165 STREET, MIAMI, FL 33162 (NAICS 561990). OSHA activity number 345863989.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J&P Marine Construction, INC. — free Get an email when a new federal OSHA severe-injury report for J&P Marine Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3281 NORTH 165 STREET
City
MIAMI
State
FL
ZIP
33162
Mailing
2030 SW 96 AVE, FORT LAUDERDALE, FL 33312
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561990
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2022
Abate by
Oct 4, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:   On or about 3/24/2022, at 3281 North 165 Street Miami, FL 33162; an employee using a handheld grinder while submerged in approximately 12 inches of water and was not trained on how to recognize and avoid an electrocution hazard.
Recent events (1)
  • — Z (S) $0

1926.106 A

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2022
Abate by
Oct 4, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.106(a):Employee(s) working over or near water where the danger of drowning existed, were not provided with U.S. Coast Guard approved life jacket(s) or buoyant work vest(s):  On or about 3/24/2022, at 3281 North 165 Street Miami, FL 33162; employees were exposed to a drowning hazard while replacing a wooden seawall dock, working in and above water at a depth of 4 feet without the use of a life jacket or buoyant work vests.
Recent events (1)
  • — Z (S) $0

1926.300 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2022
Abate by
Oct 4, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.300(b)(1):Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:  On or about 3/24/2022, at 3281 North 165 Street Miami, FL 33162; an employee was exposed to amputation, laceration, and struck-by hazards while using an ordinary handheld portable grinder to cut steel bolts with no guard installed.
Recent events (1)
  • — Z (S) $0

1926.404 B01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2022
Abate by
Oct 4, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR  1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.  On or about 3/24/2022, at 3281 North 165 Street Miami, FL 33162; employer did not ensure the use of a ground fault circuit interrupter for employees who were exposed to an electrical hazard while using a hand powered tool.
Recent events (1)
  • — Z (S) $4351

1926.416 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 15, 2022
Abate by
Oct 4, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.416(e)(1):Worn or frayed electric cords or cables were used:  On or about 3/24/2022, at 3281 North 165 Street Miami, FL 33162; employees were exposed to an electrical hazard while replacing a wooden dock using a handheld grinder powered by a damaged electrical extension cord, with exposed conductors.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345863989.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.