Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MIAMI VALLEY STEEL SERVICE, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MIAMI VALLEY STEEL SERVICE, INC. in 201 FOX DRIVE, PIQUA, OH 45356 (NAICS 331221). OSHA activity number 345865604.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Miami Valley Steel Service, INC. — free Get an email when a new federal OSHA severe-injury report for Miami Valley Steel Service, INC. is published. One employer, no account, unsubscribe in one click.
Site address
201 FOX DRIVE
City
PIQUA
State
OH
ZIP
45356
Mailing
201 FOX DRIVE, PIQUA, OH 45356
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
Employees
135
Ownership type
A

1 citation on file for this inspection.

1910.212 A01

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Jun 24, 2022
Abate by
Sep 28, 2022
Penalty
Initial $11,747 · Current $9,000 Reduced
29 CFR  1910.212(a)(1):Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.  a) On 03/23/2022, the employer did not properly guard the Do James Re-coiler for the Torrington Slitter , in that the pressure mats did not protect employee while utilizing the controls on the  overarm, resulting in employees being exposed to a caught-in-hazard.  b) On or about 03/23/2022 the employer did not properly guard the Do James Re-coiler for the Wean Slitter, in that the pressure mats did not protect employees while utilizing the controls on the overarm, resulting in employees being exposed to a caught-in-hazard.
Recent events (3)
  • — P (O) $9000
  • — I (O) $9000
  • — Z (S) $11747

View Miami Valley Steel Service, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345865604.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.