Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: G B UNDERGROUND LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of G B UNDERGROUND LLC in 1957 CULEBRA ROAD, AUSTIN, TX 78747 (NAICS 237110). OSHA activity number 345869374.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G B Underground LLC — free Get an email when a new federal OSHA severe-injury report for G B Underground LLC is published. One employer, no account, unsubscribe in one click.
Establishment
G B UNDERGROUND LLC
Site address
1957 CULEBRA ROAD
City
AUSTIN
State
TX
ZIP
78747
Mailing
11009 MICKELSON DRIVE, AUSTIN, TX 78747
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
15
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Other-than-serious Gravity 5 1 instance 5 exposed
Issued
Jun 10, 2022
Penalty
Initial $3,315 · Current $1,650 Reduced
29 CFR  1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:    At Project #4024 : On or about March 30, 2022, and at times prior thereto, employees were exposed to a caught-in hazard while removing soil from around the existing main water line without having a ladder for safe access and egress from the trench.
Recent events (3)
  • — C (S) $3315
  • — F (O) $1650
  • — Z (S) $3315

1926.651 K01

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Jun 10, 2022
Abate by
Jun 30, 2022
Penalty
Initial $3,315 · Current $1,650 Reduced
29 CFR  1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift:  On or about March 30, 2022 employees were exposed to a caught-in hazard while working inside an excavation that was not inspected by a competent person to identify trenching and excavation hazards.
Recent events (3)
  • — C (S) $3315
  • — F (O) $1650
  • — Z (S) $3315

1926.652 A01

Other-than-serious Gravity 5 2 instances 4 exposed
Issued
Jun 10, 2022
Penalty
Initial $4,972 · Current $2,500 Reduced
29 CFR  1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c):   At Project #4024: On or about March 30, 2022, and at times prior thereto, employees were exposed to a caught-in hazard while performing utility work on a water line without having trench protection in a vertical wall trench at a depth over five feet.
Recent events (3)
  • — C (S) $4972
  • — F (O) $2500
  • — Z (S) $4972

View G B Underground LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345869374.