LITTLETON, CO —
OSHA Inspection: COLOCORP BUILDERS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COLOCORP BUILDERS LLC in 8211 SOUTHPARK CIR., LITTLETON, CO 80120 (NAICS 238910). OSHA activity number 345871669.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COLOCORP BUILDERS LLC
- Site address
- 8211 SOUTHPARK CIR.
- City
- LITTLETON
- State
- CO
- ZIP
- 80120
- Mailing
- 9609 S. UNIVERSITY BLVD., #630740, LITTLETON, CO 80163
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 1
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.652 A01
- Issued
- May 26, 2022
- Abate by
- Jul 18, 2022
- Penalty
- Initial $3,729 · Current $3,729
General-duty citation text
29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): (a) Colocorp Builders LLC at 8211 Southpark Cir. Littleton, CO 80120: On or before 4/1/22 the controlling and correcting employer did not protect subcontractor employees from injury in that a retaining wall was being erected against the side of a hill with a vertical cut wall measuring approximately 15 feet tall. Subcontractor employees were working within 15 feet of the face of this wall, raking gravel and laying CMU block. The vertical cut wall showed signs of fissuring and sloughing and was not sloped, benched, or shored in accordance with this standard. The vertical cut wall had been cut more than 90 days prior to the date of the inspection and storm systems had effected the integrity of the vertical earthen wall. These conditions exposed subcontractor employees to struck-by, falling object, and cave-in hazards. Abatement Note: Abatement certification is required for this item, see enclosed "Certification of Corrective Actions Worksheet."
Recent events (1)
- — Z (S) $3729
More inspections at Colocorp Builders LLC
View Colocorp Builders LLC's full OSHA safety record →
More inspections in this industry (NAICS 238910)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345871669.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.