LITTLETON, CO —
OSHA Inspection: MILLER WALL COMPANY
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of MILLER WALL COMPANY in 8211 SOUTHPARK CIR., LITTLETON, CO 80120 (NAICS 237990). OSHA activity number 345871842.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MILLER WALL COMPANY
- Site address
- 8211 SOUTHPARK CIR.
- City
- LITTLETON
- State
- CO
- ZIP
- 80120
- Mailing
- PO BOX 211368, DENVER, CO 80221
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237990
- Employees
- 6
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.652 A01
- Issued
- May 26, 2022
- Abate by
- Jul 18, 2022
- Penalty
- Initial $4,227 · Current $3,500 Reduced
General-duty citation text
29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): Miller Wall Company at 8211 Southpark Cir. Littleton, CO 80120: On or before 4/1/22 the controlling and correcting employer did not protect employees from injury in that a retaining wall was being erected against the side of a hill with a vertical cut wall measuring approximately 15 feet tall. Employees were working within 15 feet of the face of this wall, raking gravel and laying CMU block. The vertical cut wall showed signs of fissuring and sloughing and was not sloped, benched, or shored in accordance with this standard. The vertical cut wall had been cut more than 90 days prior to the date of the inspection and storm systems had effected the integrity of the vertical earthen wall. These conditions exposed employees to struck-by, falling object, and cave-in hazards. Abatement Note: Abatement certification is required for this item, see enclosed "Certification of Corrective Actions Worksheet."
Recent events (2)
- — I (O) $3500
- — Z (S) $4227
More inspections in this industry (NAICS 237990)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345871842.