Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BELLOWS AIR FORCE STATION, 18TH FORCE SUPPORT SQUADRON-DETACHMENT 2

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BELLOWS AIR FORCE STATION, 18TH FORCE SUPPORT SQUADRON-DETACHMENT 2 in 515 TINKER ROAD, WAIMANALO, HI 96795 (NAICS 721110). OSHA activity number 345871941.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bellows AIR Force Station, 18TH Force Support Squadron-Detachment 2 — free Get an email when a new federal OSHA severe-injury report for Bellows AIR Force Station, 18TH Force Support Squadron-Detachment 2 is published. One employer, no account, unsubscribe in one click.
Site address
515 TINKER ROAD
City
WAIMANALO
State
HI
ZIP
96795
Mailing
515 TINKER ROAD, WAIMANALO, HI 96795
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
114
Ownership type
D

8 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 29, 2022
Abate by
May 25, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Logistics Building: The blade on the Dewalt deep cut portable  bandsaw serial number 275433 used for metal fabrication was not guarded.  Employees were exposed to ingoing nip point, and amputation hazards.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 29, 2022
Abate by
May 11, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Building 543 Woodshop: Multiple Dewalt, Milwaukee, and Ridged battery chargers were plugged into two series connected "daisy chained" relocatable power taps.  Employees were exposed to fire and electrical hazards.
Recent events (1)
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 29, 2022
Abate by
May 25, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  Logistics Building: A circuit breaker/cover was missing from slot 21 in the electrical box with a broken door latch to the right of the Logistic Managers office.  Employees were exposed to electrical hazards.
Recent events (1)
  • — Z (S) $0

1910.1200 F06 II

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 29, 2022
Abate by
May 18, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical  Building #508: An unlabeled bottle said to contain a hazardous chemical used for cleaning surfaces inside the laundry room and cottages was not labeled. Employees were exposed to chemical hazards.
Recent events (1)
  • — Z (S) $0

1904.40 A

Other-than-serious 1 instance 25 exposed
Issued
Apr 29, 2022
Abate by
May 11, 2022
Penalty
Initial $0 · Current $0
29 CFR  1904.40(a): The employer did not provide an authorized government representative the records within the four business hours.  The injury and illness were not provided when requested on March 30, 2022, while on site; April 1, 2022, via email and phone call; or April 11, and April 20, 2022 via email.
Recent events (1)
  • — Z (O) $0

1910.303 G01

Other-than-serious 2 instances 6 exposed
Issued
Apr 29, 2022
Abate by
May 11, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a. Building #508: Electrical panel L was blocked by a table and plastic shelving. Access was restricted in the event of an emergency.  b. Turtle Cove Rental Building: The electrical panel outside of the supervisor office was blocked by boxes of disposable cups. Access was restricted in the event of an emergency.
Recent events (1)
  • — Z (O) $0

1910.1200 E01 I

Other-than-serious 1 instance 3 exposed
Issued
Apr 29, 2022
Abate by
May 18, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(e)(1)(i):The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.  Logistics Building: A list of all hazardous chemicals maintained in the facility was not developed, exposing employees to chemical hazards.
Recent events (1)
  • — Z (O) $0

1910.1200 G08

Other-than-serious 1 instance 3 exposed
Issued
Apr 29, 2022
Abate by
May 18, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(g)(8):  The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical  Logistics Building: The safety data sheet for Purple Power Degreaser and various other chemicals were not maintained. Employees were exposed to chemical hazards.
Recent events (1)
  • — Z (O) $0

View Bellows AIR Force Station, 18TH Force Support Squadron-Detachment 2's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345871941.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.