Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J.M. YOUNG & SONS, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of J.M. YOUNG & SONS, INC. in 1430 HARRISBURG PIKE, LANCASTER, PA 17601 (NAICS 238160). OSHA activity number 345876080.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J.M. Young & Sons, INC. — free Get an email when a new federal OSHA severe-injury report for J.M. Young & Sons, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1430 HARRISBURG PIKE
City
LANCASTER
State
PA
ZIP
17601
Mailing
P.O. BOX 808, BELLEVILLE, PA 17004
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 2, 2022
Abate by
Jun 29, 2022
Penalty
Initial $11,167 · Current $11,167
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, warning line system and personal fall arrest system, or warning line system and safety monitoring system; or, on roofs 50 feet (15.25 m) or less in width, the use of a safety monitoring system alone:  a) Roof - Roofers were observed dumping materials over the edge of a flat roof 18 feet above ground and were not protected from fall hazards, on or about April 4, 2022.  Abatement certification and documentation required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $11167

1926.502 F01

Serious Gravity 10 2 instances 6 exposed
Issued
Jun 2, 2022
Penalty
Initial $11,167 · Current $11,167
29 CFR  1926.502(f)(1): Warning lines were not erected around all sides of the roof work area:  a) Roof - Employees were performing roofing activities on a flat roof with a warning line system that was not erected around all sides of the work area located 18 feet above ground. At the north end of the warning line system a 43 inch wide opening was observed between the stanchion and parapet wall, on or about April 4, 2022.  b) Roof - Employees were performing roofing activities on a flat roof with a warning line system that was not erected around all sides of the work area located 18 feet above ground. At the south end of the warning line system a 58 inch wide opening was observed between the stanchion and parapet wall, on or about April 4, 2022.  No abatement certification or documentation required.
Recent events (1)
  • — Z (S) $11167

1926.502 F01 II

Serious Gravity 10 1 instance 6 exposed
Issued
Jun 2, 2022
Penalty
Initial $0 · Current $0
29 CFR 1926.502(f)(1)(ii): When mechanical equipment was being used, the warning line was not erected at least 6 feet (1.8 m) from the roof edge which is parallel to the direction of mechanical equipment operation, and at least 10 feet (3.1 m) from the roof edge which is perpendicular to the direction of mechanical equipment operation:  a) Roof - Roofers tore off sections of the roof using an Enforcer Twin Saw and the warning line was not erected at least 10 feet from the roof edge which was perpendicular to the direction of mechanical equipment operation, on or about April 4, 2022.   No abatement certification or documentation required.
Recent events (1)
  • — Z (S) $0

1926.502 F01 III

Serious Gravity 10 1 instance 6 exposed
Issued
Jun 2, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.502(f)(1)(iii): Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines:   a) Roof - Roofers used a portable extension ladder to access/egress the roof while not having the access point demarcated by two warning lines and were exposed to an 18 foot fall hazard to the ground below, on or about April 4, 2022.   No abatement certification or documentation required.
Recent events (1)
  • — Z (S) $0

1926.502 F01 IV

Serious Gravity 10 1 instance 6 exposed
Issued
Jun 2, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.502(f)(1)(iv): When the path to the point of access was not in use, a rope, wire, chain, or other barricade, equivalent in strength and height to the warning line, was not placed across the path at the point where the path intersected the warning line erected around the work area, or the path was not offset such that a person cannot walk directly into the work area:    a) Roof - When not in use the chain was not placed across the path to the point of access at the material handling area, exposing employees to an 18 foot fall hazard to the ground below, on or about April 4, 2022.  No abatement certification or documentation required.
Recent events (1)
  • — Z (S) $0

1926.502 F02 II

Serious Gravity 10 2 instances 6 exposed
Issued
Jun 2, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.502(f)(2)(ii): The rope, wire, or chain was not rigged or supported in such a way that its lowest point (including sag) was not less than 34 inches (0.9 m) from the walking/working surface and its highest point no more than 39 inches (1.0 m) from the walking/working surface.   a) Roof - At the north end of the warning line system the line measured  32 inches high from the walking/working surface of the roof, on or about April 4, 2022.   b) Roof - At the south end of the warning line system the line measure 18 1/2 inches high from the walking/working surface of the roof, on or about April 4, 2022.   No abatement certification or documentation required.
Recent events (1)
  • — Z (S) $0

View J.M. Young & Sons, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345876080.