OSHA Inspection: TIGHE LOGISTICS GROUP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TIGHE LOGISTICS GROUP in 45 HOLTON STREET, WINCHESTER, MA 01890 (NAICS 493110). OSHA activity number 345879381.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tighe Logistics Group — free Get an email when a new federal OSHA severe-injury report for Tighe Logistics Group is published. One employer, no account, unsubscribe in one click.
Site address
45 HOLTON STREET
City
WINCHESTER
State
MA
ZIP
01890
Mailing
481 WILDWOOD AVE, WOBURN, MA 01801
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
10
Ownership type
A

7 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 4, 2022
Abate by
Aug 23, 2022
Penalty
Initial $14,502 · Current $7,250 Reduced
29 CFR  1910.28(b)(1)(i):  Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):  (a) Location - Second floor storage area: On or about 04/06/2022, employees were exposed to falls greater than 10 feet from the ground  on second floor storage area.
Recent events (2)
  • — I (S) $7250
  • — Z (S) $14502

1910.178 A06

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 4, 2022
Abate by
Aug 23, 2022
Penalty
Initial $6,215 · Current $3,700 Reduced
29 CFR  1910.178(a)(6): The employer did not ensure that all nameplates and markings were in place:   (a) Location - First Floor main storage area: On or about 04/06/2022, an employee was operating a powered industrial truck (forklift) and the identification tag was not legible.
Recent events (2)
  • — I (S) $3700
  • — Z (S) $6215

1910.178 Q01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 4, 2022
Abate by
Aug 23, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.178(q)(1):Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: (a) Location - Warehouse: On or about 04/06/2022, the employer did not remove a powered industrial truck that was not in safe operating condition (leaks and faulty brakes).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.110 F02 II

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 4, 2022
Abate by
Aug 23, 2022
Penalty
Initial $10,360 · Current $6,200 Reduced
29 CFR  1910.110(f)(2)(ii): Liquefied petroleum gas container(s) stored inside were located near exits, stairways, or in areas normally used or intended for the safe exit of people:   (a) Location - Warehouse exit  On or about 04/06/20222, employer was storing propane cylinders under stairs in front of exit.
Recent events (2)
  • — I (S) $6200
  • — Z (S) $10360

1910.303 F02

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 4, 2022
Abate by
Aug 23, 2022
Penalty
Initial $8,287 · Current $5,150 Reduced
29 CFR  1910.303(f)(2):Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Location - 2nd floor storage area:  On or about 04/06/2022, employees were exposed electrical hazards when each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.
Recent events (2)
  • — I (S) $5150
  • — Z (S) $8287

1910.303 G02 I

Serious Gravity 10 1 instance 4 exposed
Issued
Aug 4, 2022
Abate by
Aug 23, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.303(g)(2)(i):Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  (a) Location - 2nd floor storage area: On or about 04/06/2022, the employer did not guard live electrical parts from accidental contact. The cover on an energized electrical outlet was missing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 4, 2022
Abate by
Aug 23, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed:  (a) Location - 2nd floor storage area: On or about 04/06/2022, the unused openings in electrical panels, cabinets, and motor control centers were not effectively closed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0