GRAND JUNCTION, CO —
OSHA Inspection: CCI CAPCO, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CCI CAPCO, LLC in 1328 WINTERS AVENUE, GRAND JUNCTION, CO 81501 (NAICS 325920). OSHA activity number 345884266.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CCI CAPCO, LLC
- Site address
- 1328 WINTERS AVENUE
- City
- GRAND JUNCTION
- State
- CO
- ZIP
- 81501
- Mailing
- 1328 WINTERS AVENUE, GRAND JUNCTION, CO 81501
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325920
- Employees
- 350
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.119 E06
- Issued
- Sep 22, 2022
- Abate by
- Dec 1, 2022
- Penalty
- Initial $14,502 · Current $11,602 Reduced
General-duty citation text
29 CFR 1910.119(e)(6): The employer did not update and revalidate by a team meeting the requirements in paragraph (e)(4) of this section, to assure that the process hazard analysis is consistent with the current process, at least every five (5) years after the completion of the initial process hazard analysis: (a) On and before April 6, 2022, the employer did ensure an update and revalidation of the process hazard analysis was conducted at least every five (5) years by a team meeting the requirements in paragraph (e)(4) of 29 CFR 1910.119, to assure that the process hazard analysis was consistent with the current process of the Load & Press Initiation of BBU-48. This condition exposed employees to injuries associated with a deflagration event of a Division 1.3 explosive blend. (b) On April 6, 2022, an employee in the Energetics Loading Room (ELR) was loading a Division 1.3 explosive blend, TBK Initiation Powder, into a BBU-48 Dual Impulse Cartridge. The employee was clearing the funnel that is used to load the explosive blend into the Dual Impulse Cartridge when a glancing blow between the handheld tool and funnel caused a deflagration event. This condition led to an employee sustaining second and third degree burns of the hands and arms.
Recent events (2)
- — I (O) $11601.5
- — Z (S) $14502
1910.132 D01
- Issued
- Sep 22, 2022
- Abate by
- Dec 1, 2022
- Penalty
- Initial $14,502 · Current $11,602 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): (a) On and before April 6, 2022, the employer did not assess the workplace for hazards that are present or likely to be present, which necessitate the use of personal protective equipment, including, but not limited to, the process and associated hazards with the Load & Press Initiation of BBU-48 in the Energetic Loading Room (ELR), while loading a 1.3 explosive blend. This condition exposed employees to injuries including, but not limited to, burns and concussion. (b) On April 6, 2022, an employee in the Energetics Loading Room (ELR) was loading a Division 1.3 explosive blend, TBK Initiation Powder, into a BBU-48 Dual Impulse Cartridge. The employee was clearing the funnel that is used to load the explosive blend into the Dual Impulse Cartridge when a glancing blow between the handheld tool and funnel caused a deflagration event. This condition led to an employee sustaining second and third degree burns of the hands and arms.
Recent events (2)
- — I (O) $11601.5
- — Z (S) $14502
1910.138 A
- Issued
- Sep 22, 2022
- Abate by
- Dec 1, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes: (a) On and before April 6, 2022, the employer did not select and require employees to use appropriate hand protection in the Energetic Loading Room (ELR), while loading a 1.3 explosive blend in to BBU-48 Dual Impulse Cartridges. This condition exposed employees to injuries including, but not limited to, burns. (b) On April 6, 2022, an employee in the Energetics Loading Room (ELR) was loading a Division 1.3 explosive blend, TBK Initiation Powder, in to a BBU-48 Dual Impulse Cartridge. The employee was clearing the funnel that is used to load the explosive blend into the Dual Impulse Cartridge when a glancing blow between the handheld tool and funnel caused a deflagration event. This condition led to an employee sustaining second and third degree burns of the hands and arms.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at CCI Capco, LLC
View CCI Capco, LLC's full OSHA safety record →
More inspections in this industry (NAICS 325920)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345884266.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.