TULSA, OK —
OSHA Inspection: HOFFMAN FIXTURES COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HOFFMAN FIXTURES COMPANY in 6031 SOUTH 129TH EAST AVENUE, TULSA, OK 74134 (NAICS 337110). OSHA activity number 345887707.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HOFFMAN FIXTURES COMPANY
- Site address
- 6031 SOUTH 129TH EAST AVENUE
- City
- TULSA
- State
- OK
- ZIP
- 74134
- Mailing
- 6031 SOUTH 129TH EAST AVENUE, TULSA, OK 74134
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 35
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.37 A01
- Issued
- Jul 29, 2022
- Abate by
- Aug 10, 2022
- Penalty
- Initial $4,351 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.37(a)(1): Exit routes must be kept free of explosive or highly flammable furnishings or other decorations: On or about April 6, 2022, and at times prior thereto, in the granite storage area, propane cylinders were stored inside the building next to the fire exit door. This exposed employees to a fire hazard.
Recent events (2)
- — I (O) $2000
- — Z (S) $4351
1910.213 B03
- Issued
- Jul 29, 2022
- Abate by
- Sep 15, 2022
- Penalty
- Initial $5,801 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure: On or about April 6, 2022, and at times prior thereto, employees were in use of wood working machines that did not have an "anti-restart" device installed to prevent the machine from automatically restarting upon restoration of power after a power failure, including but not limited to the following instances: a) A table saw in the Solid Surface area did not have an "anti-restart" device installed. b) A radial arm saw in the Solid Surface area did not have an "anti-restart" device installed. This exposed employees to amputation hazards.
Recent events (2)
- — I (O) $3000
- — Z (S) $5801
1910.213 D01
- Issued
- Jul 29, 2022
- Abate by
- Aug 17, 2022
- Penalty
- Initial $5,801 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: On or about April 6, 2022, and at times prior thereto, in the Solid Surface area, employees were in use of a table saw, used to cut lumber, that did not have a guard installed. This exposed the employees to an amputation hazard.
Recent events (2)
- — I (S) $3000
- — Z (S) $5801
1910.219 D01
- Issued
- Jul 29, 2022
- Abate by
- Aug 17, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about April 6, 2022, and at times prior thereto, in the Solid Surface area, employees were in use of a table saw with an unguarded belt and pulley on the motor. This exposed the employees to an amputation hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 H01
- Issued
- Jul 29, 2022
- Abate by
- Aug 17, 2022
- Penalty
- Initial $5,801 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material being cut: On or about April 6, 2022, and at times prior thereto, in the Solid Surface area, employees were in use of a radial arm saw that did not have the lower blade guards installed. This exposed the employees to an amputation hazard.
Recent events (2)
- — I (O) $3000
- — Z (S) $5801
1910.213 H04
- Issued
- Jul 29, 2022
- Abate by
- Aug 17, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator: On or about April 6, 2022, and at times prior thereto, in the Solid Surface area, employees were in use of a radial arm saw that was not installed in a manner that would cause the cutting head to gently return to the starting position when released by the operator. This exposed the employees to an amputation hazard.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.22 A01
- Issued
- Jul 29, 2022
- Abate by
- Aug 10, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition: On or about April 6, 2022, and at times prior thereto, in the Solid Surface area, wood Corian dust was accumulated on the floor and electrical outlet box. This exposed the employees to a explosion/fire hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.307 C
- Issued
- Jul 29, 2022
- Abate by
- Aug 10, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: On or about April 6, 2022, and at times prior thereto, in the Solid Surface area, an electrical outlet was not intrinsically safe for the hazardous location. This exposed the employees to a explosion/fire hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 337110)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345887707.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.