SOUTH PLAINFIELD, NJ —
OSHA Inspection: SUNRUN INSTALLATION SERVICES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SUNRUN INSTALLATION SERVICES, INC. in 1101 MAPLE AVE., SOUTH PLAINFIELD, NJ 07080 (NAICS 221114). OSHA activity number 345895601.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUNRUN INSTALLATION SERVICES, INC.
- Site address
- 1101 MAPLE AVE.
- City
- SOUTH PLAINFIELD
- State
- NJ
- ZIP
- 07080
- Mailing
- 26 WORLD FAIR DRIVE, UNIT K, SOMERSET, NJ 08873
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 221114
- Employees
- 25
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.100 A
- Issued
- Jun 24, 2022
- Penalty
- Initial $12,431 · Current $12,431
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects: a. 1101 Maple Ave., South Plainfield, NJ The employer did not ensure that employees were protected from falling or flying objects which could cause head injuries. Employees engaged in the installation of solar panels, working directly below employees receiving materials to the roof, were not protected by use of hardhats. Violation observed on or about April 13, 2022
Recent events (3)
- — J (O) $12431
- — C (S) $12431
- — Z (S) $12431
1926.501 B13
- Issued
- Jun 24, 2022
- Penalty
- Initial $14,502 · Current $14,502
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. 1101 Maple Ave., South Plainfield, NJ - Roof The employer did not ensure that employees were protected from falls. Employees engaged in residential solar panel installation activities worked at the edge at heights greater than 6 feet and were not protected from falls by use of a personal fall arrest system or guardrail system. Violation observed on or about April 13, 2022
Recent events (3)
- — J (O) $14502
- — C (S) $14502
- — Z (S) $14502
More inspections at Sunrun Installation Services, INC.
View Sunrun Installation Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 221114)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345895601.