Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLLIER METALS, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of COLLIER METALS, LLC in 793 WINDSOR STREET SW, ATLANTA, GA 30315 (NAICS 331221). OSHA activity number 345896302.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Collier Metals, LLC — free Get an email when a new federal OSHA severe-injury report for Collier Metals, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
COLLIER METALS, LLC
Site address
793 WINDSOR STREET SW
City
ATLANTA
State
GA
ZIP
30315
Mailing
793 WINDSOR STREET SW, ATLANTA, GA 30315
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
Employees
19
Ownership type
A

6 citations on file for this inspection.

1910.28 B07

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 5, 2022
Abate by
Nov 1, 2022
Penalty
Initial $3,315 · Current $2,500 Reduced
29 CFR  1910.28(b)(7):  The employer did not ensure that each employee on a walking-working surface near an opening, including one with a chute attached, where the inside bottom edge of the opening is less than 39 inches (99 cm) above that walking-working surface and the outside bottom edge of the opening is 4 feet (1.2 m) or more above a lower level is protected from falling by the use of one of the systems listed in 29 CFR 1910.28(b)(7)(i)-(iv).    a) 72-inch Steel Slitter Line, Coil car pit: On or about 04/13/2022, and at times prior, the employer exposed employees to fall hazards of approximately 59-inches to the bottom of the pit, in that a fall protection system was not provided along all open sides of the 5-ft. wide by 9-ft, long pit.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3315

1910.28 B11 II

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 5, 2022
Abate by
Oct 18, 2022
Penalty
Initial $3,315 · Current $2,500 Reduced
29 CFR  1910.28(b)(11)(ii): The employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as described in 29 CFR 1910.28 Table D-2-Stairway Handrail Requirements.    a) 72-inch Steel Slitter Line, Wooden steps to Slitter platform: On or about 04/13/2022, and at times prior, the employer exposed employees to fall hazards of approximately 46-inches to the lower concrete surface, in that stair rails were not provided along the open sides of the wooden stairway provided to the Slitter platform.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3315

1910.178 P01

Serious Gravity 5 1 instance 4 exposed
Issued
Oct 5, 2022
Abate by
Nov 1, 2022
Penalty
Initial $3,315 · Current $2,500 Reduced
29 CFR  1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition:  (a) Collier Metals LLC Plant: On or about 04/13/2022, the employer did not ensure that the Komatsu (Model FD45T-8) Forklift Truck which was in need of repair due to defective or non-operable horns, broken windshield, and torn operator's seat was not taken out of service until it had been restored to safe operating conditions. This condition exposed employees to a struck-by hazard.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3315

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 5, 2022
Abate by
Nov 1, 2022
Penalty
Initial $14,502 · Current $11,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) 72-inch Steel Slitter Line, Re-coiler area: On or about 04/13/2022, and at times prior, the employer exposed employees to caught-in/entanglement hazards from unguarded rotating parts, in that the employer did not provide adequate guarding or safe guards to protect employees from leaning or reaching into the recoil drum or metal roll while in operation.
Recent events (2)
  • — I (S) $11000
  • — Z (S) $14502

1910.303 G02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 5, 2022
Abate by
Oct 18, 2022
Penalty
Initial $2,486 · Current $1,750 Reduced
29 CFR  1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):   a) 72-inch Steel Slitter Line, Solenoid Valve: On or about 04/13/2022, and at times prior, the employer exposed employees to electrical/burn hazards near the coil cart pit area, in that employees were exposed to 120v electrical wiring which provided power to a solenoid which was not provided with a cover or enclosure to prevent accidental contact by employees engaged in metal slitting operations.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $2486

1910.334 A02 II

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 5, 2022
Abate by
Nov 1, 2022
Penalty
Initial $2,486 · Current $1,750 Reduced
29 CFR  1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made:   a) 72-inch Steel Slitter Line, Portable Hydraulic Unit used at Re-coiler drum: On or about 04/13/2022, and at times prior, the employer exposed employees to electrical/burn hazards, in that energized flexible cords used to provide power to the hydraulic unit had torn and frayed wires, missing ground pin and improperly repaired casing with masking tape used for repairs. The employer failed to remove these cords from service until repaired.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $2486