Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LEVEL SMART FOUNDATION REPAIR

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of LEVEL SMART FOUNDATION REPAIR in 1162 HOLMES COURT, AUSTIN, TX 78702 (NAICS 238190). OSHA activity number 345897466.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Level Smart Foundation Repair — free Get an email when a new federal OSHA severe-injury report for Level Smart Foundation Repair is published. One employer, no account, unsubscribe in one click.
Site address
1162 HOLMES COURT
City
AUSTIN
State
TX
ZIP
78702
Mailing
8702 BALCONES CLUB DRIVE, AUSTIN, TX 78750
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
Yes
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
9
Ownership type
A

4 citations on file for this inspection.

1926.403 B01 III

Other-than-serious Gravity 5 2 instances 4 exposed
Issued
Aug 10, 2022
Abate by
Aug 16, 2022
Penalty
Initial $3,108 · Current $3,108
29 CFR  1926.403(b)(1)(iii): Electrical equipment was not free of recognized hazards on the basis of electrical insulation.  On or about April 9, 2022, electrical cords were used with multiple areas of damaged, cut and missing insulation, exposing the employees to an electrical hazard.  a) A drop light with black flexible cord with multiple areas of damaged insulation;  b) A yellow extension cord with multiple areas of damaged insulation.
Recent events (2)
  • — I (O) $3108
  • — Z (S) $3108

1926.404 F06

Serious Gravity 5 2 instances 4 exposed
Issued
Aug 10, 2022
Abate by
Aug 16, 2022
Penalty
Initial $3,108 · Current $3,108
29 CFR  1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous.  On or about April 9, 2022, a drop light cord and a yellow flexible cord used during foundation repair work were missing the power cord ground posts, exposing the employees to an electrical hazard.
Recent events (2)
  • — I (S) $3108
  • — Z (S) $3108

1926.405 A02 II E

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
Aug 10, 2022
Abate by
Aug 16, 2022
Penalty
Initial $3,108 · Current $3,108
29 CFR  1926.405(a)(2)(ii)(E): All lamps for general illumination shall be protected from accidental contact or breakage. Metal-case sockets shall be grounded.  On or about April 9, 2022, a drop light used during foundation repair work was missing the guard for the light bulb, exposing the employees to an electrical hazard.
Recent events (2)
  • — I (O) $3108
  • — Z (S) $3108

1926.405 G02 IV

Serious Gravity 5 2 instances 4 exposed
Issued
Aug 10, 2022
Abate by
Aug 16, 2022
Penalty
Initial $3,108 · Current $3,108
29 CFR  1926.405(g)(2)(iv): Strain Relief. Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws.  On or about April 9, 2022, flexible cords used during foundation repair work did not have strain relief, exposing the employees to an electrical hazard.  1) A drop light used during the work had strain relief damage;  2) A yellow flexible cord used during the work did not have strain relief.
Recent events (2)
  • — I (S) $3108
  • — Z (S) $3108

View Level Smart Foundation Repair's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345897466.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.