MADISON, WI —
OSHA Inspection: J.P. CULLEN & SONS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of J.P. CULLEN & SONS, INC. in 1430 MONROE STREET, MADISON, WI 53711 (NAICS 236220). OSHA activity number 345897805.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J.P. CULLEN & SONS, INC.
- Site address
- 1430 MONROE STREET
- City
- MADISON
- State
- WI
- ZIP
- 53711
- Mailing
- 330 E. DELAVAN DRIVE, JANESVILLE, WI 53547
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 40
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.152 F03
- Issued
- Sep 16, 2022
- Abate by
- Nov 9, 2022
- Penalty
- Initial $10,360 · Current $7,770 Reduced
General-duty citation text
29 CFR 1926.152(f)(3): Flammable liquids were used where there were open flames or other sources of ignition within 50 feet of the operation: Note: Certain conditions warrant that flammable liquids be used farther than 50 feet from open flames or other sources of ignition. On or about April 13, 2022, the employer did not ensure that flames or other sources of ignition were not within 50 feet of flammable liquids, including a solvent based primer being applied, resulting in a flash fire.
Recent events (2)
- — I (S) $7770
- — Z (S) $10360
1910.1200 H02 II
- Issued
- Sep 16, 2022
- Abate by
- Nov 9, 2022
- Penalty
- Initial $10,360 · Current $7,770 Reduced
General-duty citation text
29 CFR 1910.1200(h)(2)(ii): The employer did not provide information to the employees on operations in their work area where hazardous chemicals were present: (Construction Reference: 1926.59) On or about April 13, 2022, the employer did not provide information to employees about the hazardous chemicals in their work area, including a solvent based primer being applied, resulting in a flash fire.
Recent events (2)
- — I (O) $7770
- — Z (S) $10360
1910.1200 H03 I
- Issued
- Sep 16, 2022
- Abate by
- Oct 7, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(i): The employee training did not include the methods and observations used to detect the presence or release of a hazardous chemical in the work area: (Construction Reference: 1926.59) On or about April 13, 2022, the employer did not provide training to employees about the methods and observations used to detect the presence of hazardous chemicals in their work area, including a solvent based primer being applied, resulting in a flash fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H03 II
- Issued
- Sep 16, 2022
- Abate by
- Oct 7, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area: (Construction Reference: 1926.59) On or about April 13, 2022, the employer did not provide training to employees about the physical and health hazards of hazardous chemicals in their work area, including a solvent based primer being applied, resulting in a flash fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H03 III
- Issued
- Sep 16, 2022
- Abate by
- Oct 7, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used: (Construction Reference: 1926.59) On or about April 13, 2022, the employer did not provide training to employees about the the measures they can take to protect themselves form the hazards from exposure to the hazardous chemicals in their work area, including a solvent based primer being applied, resulting in a flash fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at J.P. Cullen & Sons, INC.
View J.P. Cullen & Sons, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345897805.