DENISON, TX —
OSHA Inspection: PTF INSULATION FABRICATORS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PTF INSULATION FABRICATORS in 2407 TEXOMA DRIVE, DENISON, TX 75020 (NAICS 238310). OSHA activity number 345905475.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PTF INSULATION FABRICATORS
- Site address
- 2407 TEXOMA DRIVE
- City
- DENISON
- State
- TX
- ZIP
- 75020
- Mailing
- 2407 TEXOMA DRIVE, DENISON, TX 75020
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 24
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.147 C01
- Issued
- May 16, 2022
- Abate by
- Jun 14, 2022
- Penalty
- Initial $3,315 · Current $1,989 Reduced
General-duty citation text
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. On or about April 12, 2022, and times prior thereto, the employer did not provide an energy control program to their authorized employee performing electrical work on the NGO panel board. The employee(s) were exposed to electrical hazards.
Recent events (2)
- — I (S) $1989
- — Z (S) $3315
1910.212 A03 II
- Issued
- May 16, 2022
- Abate by
- Jun 14, 2022
- Penalty
- Initial $3,315 · Current $1,989 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s). On or about April 12, 2022, and times prior thereto, two double diagonal vertical band saws were used without the unused portion of the blades not guarded exposing employees to amputation hazards. a) Vertical double blade band saw number 23 was operation with 19 inches of the blade not guarded, b) Vertical double blade band saw number 24, was in operation with 19 inches of the blade not guarded.
Recent events (2)
- — I (S) $1989
- — Z (S) $3315
1910.219 D01
- Issued
- May 16, 2022
- Penalty
- Initial $2,113 · Current $1,268 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o). On or about April 12, 2022, and times prior thereto, at the 90s machine, the employer did not ensure the pulley of the Baldor motor was guarded exposing employees to rotating pulley.
Recent events (2)
- — I (S) $1267.8
- — Z (S) $2113
1910.219 E03 I
- Issued
- May 16, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o)(a). On or about April 12, 2022, and times prior thereto, at the 90s machine, the employer did not provide a guard to protect machine operator(s) from rotating parts, exposing employee(s) to caught-by hazard(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.333 B02 IV B
- Issued
- May 16, 2022
- Abate by
- Jun 14, 2022
- Penalty
- Initial $2,486 · Current $1,492 Reduced
General-duty citation text
29 CFR 1910.333(b)(2)(iv)(B):Before circuits or equipment was worked as deenergized, a qualified person did not use test equipment to test the circuit elements and electrical parts of equipment to which employees would be exposed and did not verify that(a). On or about April 12, 2022, and times prior thereto. the employer did not ensure qualified employees tested circuits and electrical parts to ensure they were de-energized prior to installing electrical time clock to electrical panel exposing the employee to electrical hazards.
Recent events (2)
- — I (S) $1491.6
- — Z (S) $2486
1910.304 F01 VIII
- Issued
- May 16, 2022
- Abate by
- Jun 14, 2022
- Penalty
- Initial $465 · Current $279 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits were not listed and marked "SWD." On or about April 12, 2022, and times prior thereto, in the production building, west side wall, the employer allowed employees to turn fluorescent lights on and off from the electrical panel box and circuits that were not listed and marked "SWD", exposing employees to electrical shock hazards.
Recent events (2)
- — I (O) $279
- — Z (O) $465
1910.305 B01 II
- Issued
- May 16, 2022
- Penalty
- Initial $395 · Current $237 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about April 12, 2022, and times prior thereto, power box for the Baldor motor power source missing knock-out plugs exposing employees to electrical shock hazards.
Recent events (2)
- — I (O) $237
- — Z (O) $395
1910.305 B02 I
- Issued
- May 16, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: On or about April 12, 2022, and times prior thereto, in the PVC room, north side wall, heater panel box with live wires, missing cover plate exposing employees to electrical shock hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238310)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345905475.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.