HILLSBORO, IL —
OSHA Inspection: HAIER PLUMBING & HEATING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HAIER PLUMBING & HEATING, INC. in 22ND STREET @ FREY AVE, HILLSBORO, IL 62049 (NAICS 238220). OSHA activity number 345906895.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HAIER PLUMBING & HEATING, INC.
- Site address
- 22ND STREET @ FREY AVE
- City
- HILLSBORO
- State
- IL
- ZIP
- 62049
- Mailing
- 301 NORTH ELKTON STREET, OKAWVILLE, IL 62271
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 C02
- Issued
- Oct 6, 2022
- Penalty
- Initial $7,252 · Current $5,076 Reduced
General-duty citation text
29 CFR 1926.651(c)(2):A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: On or about 4/18/2022, the employer did not ensure that a safe means of egress, such as a stairway, ladder or ramp was provided for employees working in a trench that was five (5) feet, five (5) inches in depth.
Recent events (2)
- — I (S) $5076
- — Z (S) $7252
1926.652 A01
- Issued
- Oct 6, 2022
- Abate by
- Nov 10, 2022
- Penalty
- Initial $10,151 · Current $0 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Employees in excavations were not protected from cave-ins by an adequate protective system designed in accordance with paragraphs (b) sloping and benching or (c) support/shield/protective systems of this section: On or about 4/18/2022, the employer failed to provide cave-in protection such as sloping, benching, or use of a trench box when employees were working in an excavation five (5) feet, five (5) inches in depth, approximately two (2) feet wide, approximately thirty (30) feet in length, and comprised of material consistent with that of a Type C soil.
Recent events (2)
- — I (S) $0
- — Z (S) $10151
More inspections at Haier Plumbing & Heating, INC.
View Haier Plumbing & Heating, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345906895.