Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: TECTA AMERICA EAST LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TECTA AMERICA EAST LLC in 1547 7TH STREET, NW, WASHINGTON, DC 20001 (NAICS 238160). OSHA activity number 345911580.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tecta America East LLC for free Get an email when a new federal OSHA severe-injury report for Tecta America East LLC is published. One employer, no account, unsubscribe in one click.
Site address
1547 7TH STREET, NW
City
WASHINGTON
State
DC
ZIP
20001
Mailing
7340 MONTEVIDEO ROAD, JESSUP, MD 20794
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B10

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Oct 17, 2022
Abate by
Oct 24, 2022
Penalty
Initial $9,687 · Current $9,687
29 CFR  1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:  Tecta America East LLC 1547 7th St., NW Washington, DC:  a) 2nd Floor Rooftop:  On or about April 21, 2022,  employees did not have fall protection in place to prevent them from falling an estimated 29 feet to 33-feet 1inch while installing metal panel caps on top of the parapet wall.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • · I (O) $9687
  • · Z (S) $9687

1926.503 B01

Other-than-serious 1 instance 1 exposed
Issued
Oct 17, 2022
Abate by
Oct 24, 2022
Penalty
Initial $0 · Current $0
29 CFR  1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  Tecta America East LLC 1547 7th St., NW Washington, DC:  a) 2nd Floor Rooftop:  On or about April 21, 2022,  employees did not provide a written certification record with the signature of the trainer and date(s) of training for an employee exposed to an estimated 29 feet to 33-feet 1inch fall hazard while installing metal panel caps on top of the parapet wall.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Tecta America East LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 345911580.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.