DAYTON, NJ —
OSHA Inspection: EMPIRE MARBLE AND GRANITE, LLC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of EMPIRE MARBLE AND GRANITE, LLC. in 5 CHRIS CT., DAYTON, NJ 08810 (NAICS 423390). OSHA activity number 345912125.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EMPIRE MARBLE AND GRANITE, LLC.
- Site address
- 5 CHRIS CT.
- City
- DAYTON
- State
- NJ
- ZIP
- 08810
- Mailing
- 5 CHRIS CT., DAYTON, NJ 08810
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423390
- Employees
- 10
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.132 A
- Issued
- Oct 20, 2022
- Penalty
- Initial $3,729 · Current $1,832 Reduced
General-duty citation text
29 CFR 1910.132(a):Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers was not provided, used, and/or maintained. a) Empire Marble and Granite, LLC./5 Chris Crt./Dayton, NJ 08870 - Facility & Work Sites - Protective personal equipment such as a hard hat was not used during granite moving operations. Condition noted on or about 4/21/2022.
Recent events (3)
- — J (S) $1832
- — C (S) $3729
- — Z (S) $3729
1910.178 A05
- Issued
- Oct 20, 2022
- Penalty
- Initial $1,865 · Current $918 Reduced
General-duty citation text
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered. a) Empire Marble and Granite, LLC./5 Chris Court/Dayton, NJ 08870 - Facility & Work Sites - Employees were exposed to struck by hazards while granite was being transported by a Mitsubishi forklift utilizing an unapproved Aardwolf Lifting Clamp (Serial#002981) on the boom attachment. The forklift truck's data and capacity plates were not changed to reflect the clamp attachment. Condition noted on or about 4/21/2022.
Recent events (3)
- — J (S) $918
- — C (S) $1865
- — Z (S) $1865
1910.178 L01 I
- Issued
- Oct 20, 2022
- Penalty
- Initial $3,729 · Current $1,832 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). a) Empire Marble and Granite, LLC./5 Chris Crt./Dayton, NJ 08870 - Facility & Work Sites - Forklift operators were not competent to operate powered industrial trucks safely by completing the training and evaluation specified in 29 CFR 1910.178(l)(1). Company employees assisted in forklift operations by steadying the granite on the forks and standing nearby. Employees would thus be exposed to struck by hazards from improper forklift operation. Condition noted on or about 4/21/2022.
Recent events (3)
- — J (S) $1832
- — C (S) $3729
- — Z (S) $3729
1910.1200 E01
- Issued
- Oct 20, 2022
- Penalty
- Initial $1,865 · Current $918 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Empire Marble and Granite, LLC./5 Chris Court/Dayton, NJ 08870 - Facility & Work Sites: A written Hazard Communication Program was not implemented for employees exposed to chemicals, including but not limited to: - Tenax Ager -granite sealer (contains Methanol, Dibutyltin Dilaurate) - V-Max SV9 - stone adhesive (contains Vinyl Ester Resin, Styrene) - Crown Lacquer Thinner (contains Methanol, Heptane, Acetone) - etc. Condition noted on or about 4/21/2022.
Recent events (3)
- — J (S) $918
- — C (S) $1865
- — Z (S) $1865
1910.1200 G08
- Issued
- Oct 20, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not ensure that safety data sheets were readily accessible to the employees in their work area during each shift for chemicals used: a) Empire Marble and Granite, LLC./5 Chris Court/Dayton, NJ 08870 - Facility & Work Sites: The employer did not provide safety data sheets for the chemicals employees were exposed to, including but not limited to: - Tenax Ager -granite sealer (contains Methanol, Dibutyltin Dilaurate) - V-Max SV9 - stone adhesive (contains Vinyl Ester Resin, Styrene) - Crown Lacquer Thinner (contains Methanol, Heptane, Acetone) - etc. Condition noted on or about 4/21/2022.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Oct 20, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(2) and (3) on hazardous chemicals in their work at the time of their initial assignment and whenever a new hazard was introduced into their work area: a) Empire Marble and Granite, LLC./5 Chris Court/Dayton, NJ 08870 - Facility & Work Sites: Employees handling installation of finished piecework were not provided training and information for the chemicals they were exposed to, including but not limited to: - Tenax Ager -granite sealer (contains Methanol, Dibutyltin Dilaurate) - V-Max SV9 - stone adhesive (contains Vinyl Ester Resin, Styrene) - Crown Lacquer Thinner (contains Methanol, Heptane, Acetone) - etc. Condition noted on or about 4/21/2022.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 423390)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345912125.