LANCASTER, MA —
OSHA Inspection: RON BOUCHARD'S AUTO SALES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RON BOUCHARD'S AUTO SALES, INC. in 500 OLD UNION TURNPIKE, LANCASTER, MA 01523 (NAICS 811111). OSHA activity number 345912950.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RON BOUCHARD'S AUTO SALES, INC.
- Site address
- 500 OLD UNION TURNPIKE
- City
- LANCASTER
- State
- MA
- ZIP
- 01523
- Mailing
- 500 OLD UNION TURNPIKE, LANCASTER, MA 01523
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 65
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C01
- Issued
- Jun 2, 2022
- Abate by
- Jul 21, 2022
- Penalty
- Initial $7,252 · Current $3,630 Reduced
General-duty citation text
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: Honda Service, 500 Old Union Turnpike, Lancaster, MA: On April 22, 2022 and at times prior, the employer had not established an energy control program to protect employees and outside contractors who performed maintenance and servicing activities on building machinery and customer/company vehicles. Abatement Notes: Energy control procedures are required to be: - Documented for all multiple-energy source machines including the Hunter tire changer - Followed by employees including any procedures from vehicle manufacturers Energy Control training is to be documented and is required for all employees who are, or may be, in an area where energy control procedures may be utilized. A periodic inspection shall include the following elements: - Appointment of an authorized employee to inspect each local procedure for inaccuracies during an actual energy control task - A representative sampling of inspections of technicians utilizing vehicle manufacturer's procedures - A review by inspector with each authorized employee, of that employee's responsibilities under each energy control procedure they are authorized to use - Certification that the periodic inspections have been performed by identifying the machines or equipment on which the energy control procedures were being utilized, the dates of the inspections, the employees included in the inspections, and the persons performing the inspections
Recent events (2)
- — I (S) $3630
- — Z (S) $7252
More inspections in this industry (NAICS 811111)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345912950.