WASHINGTON, DC —
OSHA Inspection: VINCENTE BUILDERS, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VINCENTE BUILDERS, LLC. in 1417 MARYLAND AVENUE, NE, WASHINGTON, DC 20002 (NAICS 238130). OSHA activity number 345919682.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VINCENTE BUILDERS, LLC.
- Site address
- 1417 MARYLAND AVENUE, NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20002
- Mailing
- 8855 GARLAND AVENUE, APT-11, SILVER SPRING, MD 20901
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.20 B01
- Issued
- Aug 5, 2022
- Abate by
- Aug 24, 2022
- Penalty
- Initial $1,865 · Current $1,865
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part: a) Job Site - The employer did not have a safety and health program where employees were performing construction activity, such as but not limited to working with power tools, installing roofing material and working from ladders, on or about 04/26/2022. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $1865
1926.102 A01
- Issued
- Aug 5, 2022
- Abate by
- Aug 11, 2022
- Penalty
- Initial $1,865 · Current $1,865
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. a) Fifth Floor - The employees that were installing plywood to floor joists using a Paselode pneumatic nail gun was not wearing eye protection, on or about 04/26/2022. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $1865
1926.100 A
- Issued
- Aug 5, 2022
- Abate by
- Aug 11, 2022
- Penalty
- Initial $2,486 · Current $2,486
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Job Site - Employees that were working directly below framers on the 5th floor were not provided with head protection, on or about 04/26/2022. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $2486
1926.404 B01 I
- Issued
- Aug 5, 2022
- Abate by
- Aug 11, 2022
- Penalty
- Initial $1,865 · Current $1,865
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) Job Site - A ground fault circuit interrupter was not provide where employees were using a temporary 4-way outlet and portable electric tools including a Makita circular saw, on or about 04/26/2022. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $1865
1926.404 F06
- Issued
- Aug 5, 2022
- Abate by
- Aug 11, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6):The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) First Floor - Employees were using an extension cord that was missing the ground pin, while operating a Makita portable electric saw, on or about 04/26/2022. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $0
1926.405 B02
- Issued
- Aug 5, 2022
- Abate by
- Aug 11, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: a) First Floor - Employees were exposed to live electrical wires where the faceplate was missing from an outlet that was being used to power an electrical power saw and an air compressor, on or about 04/26/2022. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $0
1926.501 B13
- Issued
- Aug 5, 2022
- Abate by
- Aug 11, 2022
- Penalty
- Initial $4,351 · Current $4,351
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Fifth Floor - Employees were exposed to a fall hazard of approximately 50 feet while installing plywood decking without using fall protection, on or about 04/26/2022. b) All floor levels - Employees were exposed to a fall hazard of approximately 10'1" where the stairwell openings were not guarded, on or about 04/26/2022. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records. ABATEMENT DOCUMENTATION RQUIRED
Recent events (1)
- — Z (S) $4351
1926.1052 C01 II
- Issued
- Aug 5, 2022
- Abate by
- Aug 11, 2022
- Penalty
- Initial $2,486 · Current $2,486
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) First Floor - Employees were using a stairway to gain access to an upper level and there was no stair-rail system installed, exposing employees to a fall hazard of 11' 2 ", on or about 04/26/2022. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $2486
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345919682.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.