SALEM, MA —
OSHA Inspection: ORTEGA CONSTRUCTION SERVICES INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ORTEGA CONSTRUCTION SERVICES INC in 13 MESSERVEY ST., SALEM, MA 01970 (NAICS 238170). OSHA activity number 345919708.
Where did this inspection happen?
- Establishment
- ORTEGA CONSTRUCTION SERVICES INC
- Site address
- 13 MESSERVEY ST.
- City
- SALEM
- State
- MA
- ZIP
- 01970
- Mailing
- 73 4TH ST. 2ND FLOOR, LOWELL, MA 01850
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 F06
- Issued
- Penalty
- Initial $4351.00 · Current $2176.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6). Location - 13 Messervey St. Salem, Ma On or about 4/26/2022, employees on pumpjack scaffolding were not protected from potential electrical shocks or electrocution.
Recent events (2)
- — I (S) $2175.5
- — Z (S) $4351
1926.451 G01
- Issued
- Penalty
- Initial $4351.00 · Current $2176.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1):Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Location - 13 Messervey St. Salem, Ma On or about 4/26/2022, employees on pumpjack scaffolding were not protected from falls to a lower level.
Recent events (2)
- — I (S) $2175.5
- — Z (S) $4351
1926.452 J02
- Issued
- Penalty
- Initial $4351.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. Location - 13 Messervey St. Salem, Ma On or about 4/26/2022, employees on pumpjack scaffolding were not protected from potential falls by installing both top and bottom braces.
Recent events (2)
- — I (S) $0
- — Z (S) $4351
1926.1053 B01
- Issued
- Penalty
- Initial $3108.00 · Current $1554.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: Location - 13 Messervey St. Salem, Ma On or about 4/26/2022, employees using a ladder to gain access to a upper level were not protected from potential falls to a lower level. The employer did not install the ladder so that the side rails extended at least three feet above the roofline.
Recent events (2)
- — I (S) $1554
- — Z (S) $3108
1926.1053 B04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: Location - 13 Messervey St. Salem, Ma On or about 4/26/2022, employees using a ladder to gain access to a upper level were not protected from potential falls to a lower level. The employer did not install the self-supporting ladder in the open position.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B06
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level: Location - 13 Messervey St. Salem, Ma On or about 4/26/2022, employees using a ladder to gain access to a upper level were not protected from potential falls to a lower level. The employer did not secure the ladder on a unlevel surface.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238170)
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
WINSTON SALEM, NC—2026-07-09
161514 - ALPHA OMEGA CONSTRUCTION GROUP, INC
ATLANTA, GA—2026-07-09
ESV CONSTRUCTION LLC
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345919708.