IDAHO FALLS, ID —
OSHA Inspection: ARCO ELECTRIC IDAHO, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARCO ELECTRIC IDAHO, INC in 497 CAPITOL AVE, IDAHO FALLS, ID 83402 (NAICS 238210). OSHA activity number 345920961.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARCO ELECTRIC IDAHO, INC
- Site address
- 497 CAPITOL AVE
- City
- IDAHO FALLS
- State
- ID
- ZIP
- 83402
- Mailing
- PO BOX 50429, IDAHO FALLS, ID 83405
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B14
- Issued
- Jun 3, 2022
- Penalty
- Initial $2,818 · Current $1,973 Reduced
General-duty citation text
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached) where the outside bottom edge of the wall opening is 6 feet (1.8 m) or more above lower levels were not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system: a) Jobsite, second floor: On or prior to April 19, 2022 an employee working near two 24-inch-wide gaps between wall studs above an unfinished stairway, was exposed to a 14-foot fall hazard to the floor below. Note) Corrected during inspection.
Recent events (2)
- — I (S) $1972.6
- — Z (S) $2818
1926.502 B02 IV
- Issued
- Jun 3, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(b)(2)(iv): Intermediate members, were not used between posts where they were more than 19 inches (.5 m) apart; a) Jobsite, second floor: On or prior to April 19, 2022 an employee working near two 24-inch-wide gaps between the wall studs above an unfinished stairway, was exposed to a 14-foot fall hazard to the floor below. Note) Corrected during inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Arco Electric Idaho, INC
View Arco Electric Idaho, INC's full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345920961.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.