Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLECTIVO COFFEE ROASTERS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of COLECTIVO COFFEE ROASTERS, INC. in 2999 N. HUMBOLDT BLVD, MILWAUKEE, WI 53212 (NAICS 722513). OSHA activity number 345924443.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Colectivo Coffee Roasters, INC. — free Get an email when a new federal OSHA severe-injury report for Colectivo Coffee Roasters, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2999 N. HUMBOLDT BLVD
City
MILWAUKEE
State
WI
ZIP
53212
Mailing
2999 N. HUMBOLDT BLVD, MILWAUKEE, WI 53212
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722513
Employees
123
Ownership type
A

5 citations on file for this inspection.

1910.219 C02 I

Serious Gravity 5 2 instances 6 exposed
Issued
Sep 27, 2022
Abate by
Jan 3, 2023
Penalty
Initial $8,806 · Current $6,166 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  (a )On or about April 28, 2022, at the 45 coffee bean roaster,  a horizontal drive shaft located approximately Five (5) feet above the floor was not properly guarded . This  exposed employees working at, or around the machine to a caught-on and snagging hazard.  (b) On or about April 28, 2022, at the 90 coffee bean roaster,  a horizontal drive shaft located approximately Five (5) feet above the floor was not properly guarded . This  exposed employees working at, or around the machine to a caught-on and snagging hazard.
Recent events (4)
  • — P (S) $6166
  • — P (S) $6166
  • — I (S) $6166

1910.219 C04 I

Serious Gravity 5 2 instances 6 exposed
Issued
Sep 27, 2022
Abate by
Jan 3, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:  (a )On or about April 28, 2022, at the 45 coffee bean roaster,  a horizontal drive shaft with a square end protruding six (6) inches past the bearing that support the shaft and located approximately Five (5) feet above the floor was not properly guarded . This  exposed employees to a caught-on and snagging hazard.  (b) On, or about April 28, 2022 at the 90 coffee bean roaster,  a horizontal drive shaft with a square end protruding four (4) inches past the bearing that support the shaft and located approximately Five (5) feet above the floor was not properly guarded.  This exposed employees to a caught-on and snagging hazard.
Recent events (4)
  • — P (S) $0
  • — P (S) $0
  • — I (S) $0

1910.219 D01

Serious Gravity 5 2 instances 6 exposed
Issued
Sep 27, 2022
Abate by
Jan 3, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  (a )On or about April 28, 2022, at the 45 coffee bean roaster a horizontal, and vertical drive belt and pulley assembly located approximately Five (5) feet above the floor was not properly guarded. This  exposed employees to a caught-on and caught-in hazard.  (b) On or about April 28, 2022 at the 45 coffee bean roaster, a  vertical drive belt and pulley assembly with exposed spokes located approximately six (6) inches above the floor was not properly guarded. This  exposed employees to a struck-by and caught-on hazard.  (C) On or about April 28, 2022, at the 90 coffee bean roaster,  a horizontal and vertical drive belt, and pulley assembly located approximately Five (5) feet above the floor was not properly guarded. This  exposed employees to a crushing and caught-in hazard.  (d) On or about April 28, 2022, at the 90 coffee bean roaster,  a  vertical drive belt and pulley assembly with exposed spokes located approximately six (6) inches above the floor was not properly guarded. This  exposed employees to a struck-by and caught-on hazard.
Recent events (4)
  • — P (S) $0
  • — P (S) $0
  • — I (S) $0

1910.305 B01 II

Serious Gravity 5 3 instances 10 exposed
Issued
Sep 27, 2022
Penalty
Initial $8,806 · Current $3,600 Reduced
29 CFR  1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a) On or about April 28, 2022, at the 230 volt 3 phase ventilation fan control panel and disconnect located in the rear of the coffee bean roasting room, an unused opening in the front of the electrical panel was not plugged or otherwise covered. This exposed employees working at or around the panel to an electrical shock hazard.  (b) On or about April 28, 2022, at the 110 volt receptacle outlet used to supply electrical energy to the portable tankless water heater located below the employee hand wash sink, did not have a cover plate to prevent accidental access to the electrical wires and connections to the receptacle outlet. This exposed employees working at or around the receptacle  to an electrical shock hazard.  (c) On or about April 28, 2022, at the 110 volt receptacle outlet used to supply electrical energy next to the coffee grinder in the back of the coffee bean roasting room, did not have a cover plate to prevent accidental access to the electrical wires and connections to the receptacle outlet.  This exposed employees working at or around the receptacle outlet to an electrical shock hazard.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $8806

1910.303 G01 I B

Other-than-serious 2 instances 20 exposed
Issued
Sep 27, 2022
Abate by
Oct 17, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i)(B): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of the working space in front of electrical equipment was less than the width of the equipment or 762 mm (30 inches), whichever was greater :  (a) On or about April  28, 2022, adequate access area was not provided to allow employees emergency access to the electrical panels located at the back of the roasting room. Fifty (50) gallon plastic cans  used for bean storage were kept in front of the control panels. This condition did not allow sufficient entrance and access to the two 230 volt electrical panels/disconnects.  (b) On or about April  28, 2022,  adequate access area was not provided to allow employees emergency access to the electrical  circuit breaker panels located in the storage room.  Pallets were stored in front of the electrical breaker box, not allowing sufficient entrance and access to the electrical panel.
Recent events (4)
  • — P (O) $0
  • — P (O) $0
  • — I (O) $0

View Colectivo Coffee Roasters, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345924443.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.