COAL CENTER, PA —
OSHA Inspection: THE PERRYMAN COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of THE PERRYMAN COMPANY in 625 TECHNOLOGY DRIVE, COAL CENTER, PA 15423 (NAICS 331492). OSHA activity number 345926596.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE PERRYMAN COMPANY
- Site address
- 625 TECHNOLOGY DRIVE
- City
- COAL CENTER
- State
- PA
- ZIP
- 15423
- Mailing
- 625 TECHNOLOGY DRIVE, COAL CENTER, PA 15423
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331492
- Employees
- 110
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 2, 2022
- Abate by
- Apr 3, 2023
- Penalty
- Initial $14,502 · Current $7,500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to dust explosion, deflagration, or other fire hazards while working at or near dust collection systems collecting titanium fines which were not designed, installed, and located to prevent or minimize exposure in the event of a deflagration, explosion, or other uncontrolled fire event: a) In the Chip Wash Area, on or about April 27, 2022 - The three AQE4000 Overhead Cartridge Systems used to collect titanium fines from dryers were not grounded independently of the electrical grounding system. b) In the Chip Wash Area, on or about April 27, 2022 - The three AQE4000 Overhead Cartridge Systems used to collect titanium fines from dryers were dry-type cartridge filter media air-material separators (AMS). c) In the Chip Wash Area, on or about April 27, 2022 - The three AQE4000 Overhead Cartridge Systems used to collect titanium fines from dryers were not provided with isolation devices to prevent deflagration propagation between the connected equipment. d) In the Chip Wash Area, on or about April 27, 2022 - The three AQE4000 Overhead Cartridge Systems used to collect titanium fines from dryers recycled exhaust air into the building. e) In the Chip Wash Area, on or about April 27, 2022 - The three AQE4000 Overhead Cartridge Systems used to collect titanium fines from dryers were located inside the building. f) In the Chip Wash Area, on or about April 27, 2022 - The three AQE4000 Overhead Cartridge System used to collect titanium fines from dryers did not have a suppression system with control panels that had a standard battery backup of no less than 24 hours.
Recent events (2)
- — I (S) $7500
- — Z (S) $14502
1910.178 C02 VII
- Issued
- Sep 2, 2022
- Abate by
- Dec 1, 2022
- Penalty
- Initial $14,502 · Current $7,500 Reduced
General-duty citation text
29 CFR 1910.178(c)(2)(vii): Approved power-operated industrial trucks designated as DY, EE, or EX were not used in atmospheres in which combustible dust will not normally be in suspension in the air or will not be likely to be thrown into suspension by the normal operation of equipment or apparatus in quantities sufficient to produce explosive or ignitable mixtures but where deposits or accumulations of such dust may be ignited by arcs or sparks originating in the truck: a) In the Chip Wash Area, on or about April 27, 2022 - A Yale Model GLC050VXNEAE083 fork truck designated as LP was used in a Class II, Division 2 location exposing employees to dust explosion, deflagration, and other fire hazards.
Recent events (2)
- — I (S) $7500
- — Z (S) $14502
1910.178 M11
- Issued
- Sep 2, 2022
- Abate by
- Dec 1, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(m)(11): Approved industrial trucks were not used in hazardous locations: a) In the Chip Wash Area, on or about April 27, 2022 - A Yale Model GLC050VXNEAE083 fork truck designated as LP was used in a Class II, Division 2 location exposing employees to dust explosion, deflagration, and other fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.307 C
- Issued
- Sep 2, 2022
- Abate by
- Oct 21, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: a) In the Chip Wash Area, on or about April 27, 2022 - The 42EP4 exhaust fan open drip proof motors in a Class II, Division 2 location were not intrinsically safe, were not approved for the Class II, Division 2 location, or safe for the Class II, Division 2 location exposing employees to dust explosion, deflagration, and other fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at The Perryman Company
View The Perryman Company's full OSHA safety record →
More inspections in this industry (NAICS 331492)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345926596.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.