OSHA Inspection: THE PERRYMAN COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of THE PERRYMAN COMPANY in 625 TECHNOLOGY DRIVE, COAL CENTER, PA 15423 (NAICS 331492). OSHA activity number 345926596.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Perryman Company — free Get an email when a new federal OSHA severe-injury report for The Perryman Company is published. One employer, no account, unsubscribe in one click.
Site address
625 TECHNOLOGY DRIVE
City
COAL CENTER
State
PA
ZIP
15423
Mailing
625 TECHNOLOGY DRIVE, COAL CENTER, PA 15423
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331492
Employees
110
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 14 exposed
Issued
Sep 2, 2022
Abate by
Apr 3, 2023
Penalty
Initial $14,502 · Current $7,500 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to dust explosion, deflagration, or other fire hazards while working at or near dust collection systems collecting titanium fines which were not designed, installed, and located to prevent or minimize exposure in the event of a deflagration, explosion, or other uncontrolled fire event:  a) In the Chip Wash Area, on or about April 27, 2022 - The three AQE4000 Overhead Cartridge Systems used to collect titanium fines from dryers were not grounded independently of the electrical grounding system.  b) In the Chip Wash Area, on or about April 27, 2022 - The three AQE4000 Overhead Cartridge Systems used to collect titanium fines from dryers were dry-type cartridge filter media air-material separators (AMS).   c) In the Chip Wash Area, on or about April 27, 2022 - The three AQE4000 Overhead Cartridge Systems used to collect titanium fines from dryers were not provided with isolation devices to prevent deflagration propagation between the connected equipment.  d) In the Chip Wash Area, on or about April 27, 2022 - The three AQE4000 Overhead Cartridge Systems used to collect titanium fines from dryers recycled exhaust air into the building.  e) In the Chip Wash Area, on or about April 27, 2022 - The three AQE4000 Overhead Cartridge Systems used to collect titanium fines from dryers were located inside the building.  f) In the Chip Wash Area, on or about April 27, 2022 - The three AQE4000 Overhead Cartridge System used to collect titanium fines from dryers did not have a suppression system with control panels that had a standard battery backup of no less than 24 hours.
Recent events (2)
  • — I (S) $7500
  • — Z (S) $14502

1910.178 C02 VII

Serious Gravity 10 1 instance 14 exposed
Issued
Sep 2, 2022
Abate by
Dec 1, 2022
Penalty
Initial $14,502 · Current $7,500 Reduced
29 CFR  1910.178(c)(2)(vii): Approved power-operated industrial trucks designated as DY, EE, or EX were not used in atmospheres in which combustible dust will not normally be in suspension in the air or will not be likely to be thrown into suspension by the normal operation of equipment or apparatus in quantities sufficient to produce explosive or ignitable mixtures but where deposits or accumulations of such dust may be ignited by arcs or sparks originating in the truck:  a) In the Chip Wash Area, on or about April 27, 2022 - A Yale Model GLC050VXNEAE083 fork truck designated as LP was used in a Class II, Division 2 location exposing employees to dust explosion, deflagration, and other fire hazards.
Recent events (2)
  • — I (S) $7500
  • — Z (S) $14502

1910.178 M11

Serious Gravity 10 1 instance 14 exposed
Issued
Sep 2, 2022
Abate by
Dec 1, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.178(m)(11): Approved industrial trucks were not used in hazardous locations:    a) In the Chip Wash Area, on or about April 27, 2022 - A Yale Model GLC050VXNEAE083 fork truck designated as LP was used in a Class II, Division 2 location exposing employees to dust explosion, deflagration, and other fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.307 C

Serious Gravity 10 1 instance 14 exposed
Issued
Sep 2, 2022
Abate by
Oct 21, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:  a) In the Chip Wash Area, on or about April 27, 2022 - The 42EP4 exhaust fan open drip proof motors in a Class II, Division 2 location were not intrinsically safe, were not approved for the Class II, Division 2 location, or safe for the Class II, Division 2 location exposing employees to dust explosion, deflagration, and other fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View The Perryman Company's full OSHA safety record →