Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MOBILE STORE OPERATORS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MOBILE STORE OPERATORS, LLC in 128 MAIN ST, RIPLEY, WV 25271 (NAICS 811219). OSHA activity number 345933170.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mobile Store Operators, LLC — free Get an email when a new federal OSHA severe-injury report for Mobile Store Operators, LLC is published. One employer, no account, unsubscribe in one click.
Site address
128 MAIN ST
City
RIPLEY
State
WV
ZIP
25271
Mailing
800 S. DOUGLAS RD STE 450, CORAL GABLES, FL 33134
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811219
Employees
600
Ownership type
A

1 citation on file for this inspection.

1910.305 J01 I

Other-than-serious 2 instances 2 exposed
Issued
Aug 2, 2022
Abate by
Aug 26, 2022
Penalty
Initial $0 · Current $0
29 CFR  1910.305(j)(1)(i):Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact:  a) Break room East Wall: On or about May 3, 2022 and times prior, employees utilized a 120V electrical outlet to plug in charging cable and a security system.  The outlet did not have a cover or faceplate exposing the employees to energized wires.  b) Break room South Wall: On or about May 3, 2022 and times prior, employees utilized a 120V electrical outlet to plug in battery for an electric leaf blower.  The outlet did not have a cover or faceplate exposing the employees to energized wires.