On , OSHA opened a planned safety inspection of EAGLE VALLEY CONSTRUCTION in 550 FAWN VALLEY ROAD, STATE COLLEGE, PA 16801 (NAICS 238170). OSHA activity number 345937114.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EAGLE VALLEY CONSTRUCTION
- Site address
- 550 FAWN VALLEY ROAD
- City
- STATE COLLEGE
- State
- PA
- ZIP
- 16801
- Mailing
- 3260 MARSH CREEK ROAD, HOWARD, PA 16841
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 B06
- Issued
- Aug 9, 2022
- Abate by
- Aug 26, 2022
- Penalty
- Initial $2,486 · Current $2,486
General-duty citation text
29 CFR 1926.451(b)(6):On scaffolds where scaffold planks were abutted to create a long platform, each abutted end did not rest on a separate support surface: (a) 426 Fawn Valley Road State College PA Lot 550 - An employee worked from a pump jacks scaffolding to hang siding on the residential home. The scaffolding consisted of three Alum-A-Pole pump jack scaffolding, and two stage, erected across the side of the residential home, The employer attached the two platform planking together and was supported on one pump jack pole , thereby exposing the employees to injuries, on or about May 4, 2022. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $2486
1926.451 C02
- Issued
- Aug 9, 2022
- Abate by
- Aug 26, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation: (a) 426 Fawn Valley Road State College PA Lot 550 - An employee worked from a pump jacks scaffolding to hang siding on the residential home. The scaffolding consisted of three Alum-A-Pole pump jack scaffolding, and two stage, erected across the side of the residential home that was not setting on mud sills , thereby exposing the employees to injuries, on or about May 4, 2022. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1926.451 C03
- Issued
- Aug 9, 2022
- Abate by
- Aug 26, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement: (a) 426 Fawn Valley Road State College PA Lot 550 - An employee worked from a pump jacks scaffolding to hang siding on the residential home. The scaffolding consisted of three Alum-A-Pole pump jack scaffolding, that were not plumb, thereby exposing the employees to injuries, on or about May 4, 2022. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1926.451 F03
- Issued
- Aug 9, 2022
- Abate by
- Aug 26, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: (a) 426 Fawn Valley Road State College PA Lot 550 - An employee worked from a pump jacks scaffolding to hang siding on the residential home. The scaffolding consisted of three Alum-A-Pole pump jack scaffolding, and two stage/plank, erected across the side of the residential home, the competent person did not inspect the pump jack scaffold for hazards of the scaffold poles that were not setting on mud sills, was not secured at the bottom and was abutted to another stage/plank, before the employees used the pump jack scaffold, thereby exposing the employees to injuries, on or about May 4, 2022. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1926.452 J02
- Issued
- Aug 9, 2022
- Abate by
- Aug 26, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. (a) 426 Fawn Valley Road State College PA Lot 550 - Employees worked from a pump jacks scaffolding to hang siding on the residential home. The scaffolding consisted of three Alum-A-Pole pump jack scaffolding, that were not secured at the bottom to prevent the scaffold pole from moving, thereby exposing the employees to injuries, on or about May 4, 2022. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $0
1926.501 B13
- Issued
- Aug 9, 2022
- Abate by
- Aug 26, 2022
- Penalty
- Initial $4,351 · Current $4,351
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) 426 Fawn Valley Road State College PA Lot 550 - The employees were installing siding on the section of raised roof and installing scaffold bracing, on a residential home 11 feet above grade with a 6 in 12 pitch without a fall protection system in place, thereby exposing the employees to injuries, on or about May 4, 2022. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $4351
1926.1053 B01
- Issued
- Aug 9, 2022
- Abate by
- Aug 26, 2022
- Penalty
- Initial $4,351 · Current $4,351
General-duty citation text
29 CFR 1926.1053(b)(1):Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) 426 Fawn Valley Road State College PA Lot 550 - The employees were installing siding on the section of raised roof on a residential home using a n aluminum extension ladder for access and egress the roof that was not three feet above the upper landing surface, thereby exposing the employees to injuries, on or about May 4, 2022. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- — Z (S) $4351
More inspections at Eagle Valley Construction
View Eagle Valley Construction's full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345937114.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.