CONROE, TX —
OSHA Inspection: GAMALIEL LARA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GAMALIEL LARA in 2026 MYRTLE OAK COURT, CONROE, TX 77304 (NAICS 238130). OSHA activity number 345937676.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GAMALIEL LARA
- Site address
- 2026 MYRTLE OAK COURT
- City
- CONROE
- State
- TX
- ZIP
- 77304
- Mailing
- 563 WOOD MIST DRIVE, HOUSTON, TX 77013
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.102 A01
- Issued
- Jul 22, 2022
- Penalty
- Initial $3,108 · Current $1,243 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. On or about April 5, 2022, at a residential construction site in Montgomery, TX, employees were operating pneumatic nail guns without wearing appropriate eye or face protection.
Recent events (3)
- — F (O) $1243.2
- — C (S) $3108
- — Z (S) $3108
1926.451 C02
- Issued
- Jul 22, 2022
- Penalty
- Initial $3,108 · Current $1,243 Reduced
General-duty citation text
29 CFR 1926.451(c)(2):Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. On or about April 5, 2022, at a residential construction site in Montgomery, TX, employees were working from a pump jack scaffold that did not have base plates and mud sills.
Recent events (3)
- — F (O) $1243.2
- — C (S) $3108
- — Z (S) $3108
1926.451 F03
- Issued
- Jul 22, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(3):Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. On or about April 5, 2022, two employees were building a cornice from a pump jack scaffold without the scaffold being inspected by a competent person.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1926.452 J01
- Issued
- Jul 22, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(1):Pump jack brackets, braces, and accessories shall be fabricated from metal plates and angles. On or about April 5, 2022, at a residential construction site in Montgomery, TX, employees were working from a pump jack scaffold with top braces not fabricated from metal plates and angles.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1926.452 J02
- Issued
- Jul 22, 2022
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. On or about April 5, 2022, at a residential construction site in Montgomery, TX, employees were working from a pump jack scaffold that was not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Jul 22, 2022
- Penalty
- Initial $4,351 · Current $1,740 Reduced
General-duty citation text
29 CFR 1926.451(g)(1):Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. On or about April 5, 2022, at a residential construction site in Montgomery, TX, employees were working from scaffolds of more than 10 feet elevation without any fall protection systems: a. a pump jack scaffold estimated to be 12ft above ground. b. a job-made wooden scaffold estimated to be 12ft above ground.
Recent events (3)
- — F (S) $1740.4
- — C (S) $4351
- — Z (S) $4351
More inspections in this industry (NAICS 238130)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345937676.