OSHA Inspection: PA-TED SPRING COMPANY, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PA-TED SPRING COMPANY, LLC in 137 VINCENT P. KELLY ROAD, BRISTOL, CT 06010 (NAICS 332710). OSHA activity number 345944904.

Watch Pa-Ted Spring Company, LLC — free Get an email when a new federal OSHA severe-injury report for Pa-Ted Spring Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
137 VINCENT P. KELLY ROAD
City
BRISTOL
State
CT
ZIP
06010
Mailing
137 VINCENT P. KELLY ROAD, BRISTOL, CT 06010
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
24
Ownership type
A

6 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $4144.00 · Current $2000.00 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Tool Room: On or about May 9, 2022, a DoALL LT 13 Lathe was found to be missing guarding over the chuck and lead screw areas of the lathe. This condition exposed employees to hand and arm injuries associated with the operation of the machine.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4144

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.215(a)(4):Grinding machinery was not used with work rest(s) to support offhand grinding work:  Torsion Room: On or about May 9, 2022, a DeWalt bench grinder, model number DW756, serial number 200438-YL0161, was found missing a work rest, exposing employees to injuries from chips, sparks, and shattered wheel pieces.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.215(b)(9):The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  Torsion Room: On or about May 9, 2022, the tongue guard on a DeWalt bench grinder, model number DW756, serial number 200438-YL0161, was found to be missing, exposing employees to injuries from chips, sparks, and shattered wheel pieces.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3315.00 · Current $1750.00 Reduced
29 CFR  1910.215(a)(1):Abrasive wheel(s) used on grinding machinery were not used with safety guard(s):  Tool Room: On or about May 9, 2022, a Harig surface grinder, model 618 Ballway, was found operating with the guard removed, exposing employees to flying parts, sparks and injury if the wheel were to explode.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3315

1910.212 B

Other-than-serious 4 instances 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.212(b):Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  On or about May 9, 2022, there were four instances of Bridgeport Vertical Milling Machines not anchored to the floor. This condition exposed employees to injuries from the machines walking, moving, or falling over.   a) Tool Room: Bridgeport Vertical Milling Machine, serial number J312005 b) Tool Room: Bridgeport Vertical Milling Machine, serial number J311415 c) Tool Room: Bridgeport Vertical Milling Machine, serial number J121413 d) Secondary Area: Bridgeport Vertical Milling Machine, serial number J103421
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 I A

Other-than-serious 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(g)(1)(i)(A):For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:  Outside Services Area: On or about May 9, 2022, a GE disconnect switch and a GE electrical panel supplying equipment in the Torsion Room, were blocked by a transformer that was installed in front of them. Employees were exposed to possible prolonged exposure to electrical sources due to the disconnect switch and electric panel box being made more difficult to access.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345944904.