Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MULTI-COLOR CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MULTI-COLOR CORPORATION in 1102 JEFFERSON STREET, ALGOMA, WI 54201 (NAICS 325510). OSHA activity number 345946537.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Multi-Color Corporation — free Get an email when a new federal OSHA severe-injury report for Multi-Color Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1102 JEFFERSON STREET
City
ALGOMA
State
WI
ZIP
54201
Mailing
1102 JEFFERSON STREET, ALGOMA, WI 54201
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325510
Employees
350
Ownership type
A

6 citations on file for this inspection.

1910.36 G02

Deleted Serious Gravity 5 1 instance 25 exposed
Issued
Sep 30, 2022
Penalty
Initial $8,806 · Current $0 Reduced
29 CFR 1910.36(g)(2): An exit access must be at least 28 inches (71.1 cm) wide at all points. Where there is only one exit access leading to an exit or exit discharge, the width of the exit and exit discharge must be at least equal to the width of the exit access.  At an establishment located at 1102 Jefferson Street in Algoma, Wisconsin; the employer did not ensure that employees had at least 28 inches for emergency egress from the warehouse aisles to the emergency exit on the southwest corner of the building.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8806

1910.37 A03

Other-than-serious Gravity 5 1 instance 25 exposed
Issued
Sep 30, 2022
Penalty
Initial $0 · Current $1,000
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level.  At an establishment located at 1102 Jefferson Street in Algoma, Wisconsin; the employer did not ensure that exit routes were free and unobstructed. Label making materials that come in during shipments were placed temporarily within the exit routes in the warehouse.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $0

1910.176 A

Deleted Serious Gravity 5 1 instance 25 exposed
Issued
Sep 30, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.176(a): Use of mechanical equipment. Where mechanical handling equipment is used, sufficient safe clearances shall be allowed for aisles, at loading docks, through doorways and wherever turns or passage must be made. Aisles and passageways shall be kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. Permanent aisles and passageways shall be appropriately marked.  On or about May 10, 2022, at an establishment located at 1102 Jefferson Street in Algoma, Wisconsin, in the warehouse; permanent aisles used by both pedestrians and powered industrial vehicles were not appropriately marked and kept clear, exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Sep 30, 2022
Penalty
Initial $7,044 · Current $0 Reduced
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.  On or about May 10, 2022, at an establishment located at 1102 Jefferson Street in Algoma, Wisconsin, in the Finishing Department near the 30-inch Rewinder;   a) A Tripp-lite surge protector was zip tied to a support beam and not being used in accordance with the listing and labeling which required the box to be surface mounted, exposing employees to electrical shock hazards.  b) A metal electrical box was not securely mounted in accordance with the listing and labeling which require the box to be surface mounted, exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $7044

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 30, 2022
Abate by
Nov 15, 2022
Penalty
Initial $0 · Current $3,522
29 CFR 1910.305(g)(1)(iv)(A): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure.  On or about May 10, 2022, at an establishment located at 1102 Jefferson Street in Algoma, Wisconsin; the employer used a flexible cord as a substitute for the fixed wiring used to provide power to a switch and outlet hanging on the side of the 30-inch Rewinder in the Finishing Department. The flexible cord was hardwired into the switch and plugged into a Tripp-Lite SmartPro 120V Line-Interactive Uninterrupted Power Source (UPS). The outlet was providing power to a fan that blows trim waste from the Rewinder.
Recent events (2)
  • — I (S) $3522
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 30, 2022
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.  On or about May 10, 2022, at an establishment located at 1102 Jefferson Street in Algoma, Wisconsin, in the Finishing Department; the employer did not ensure that two flexible cords connected to a Tripp-Lite SmartPro 120V Line-Interactive Uninterrupted Power Source (UPS) were provided with strain relief to prevent pull from being directly transmitted to joints or terminal screws. The insulation on both flexible cords was frayed and/or disconnected from the housing of the plug.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0