KEARNY, NJ —
OSHA Inspection: SPECTRA COLORS CORP.
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of SPECTRA COLORS CORP. in 25-31 RIZZOLO RD., KEARNY, NJ 07032 (NAICS 424950). OSHA activity number 345950489.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPECTRA COLORS CORP.
- Site address
- 25-31 RIZZOLO RD.
- City
- KEARNY
- State
- NJ
- ZIP
- 07032
- Mailing
- 25-31 RIZZOLO RD., KEARNY, NJ 07032
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424950
- Employees
- 27
- Ownership type
- A
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 7, 2022
- Abate by
- Feb 15, 2023
- Penalty
- Initial $7,252 · Current $7,252
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm, including severe burns, to employees in that employees were exposed to dust explosion, deflagration, or other fire hazards from dust collectors: a) Workplace, 25 Rizzolo Road, Kearny, NJ In the Blend Room, where employees mix approximately 600 lbs of dry dye powders daily, there is a Donaldson Torit dust collector approximately 40" x 90" x 151" in size, approximately 305 ft3 in volume, used to collect dust via 3 main ducts connected to smaller ducts and local exhaust vents. This dust is explosive with a Kst Value of 7.16 Bar*Meter / sec. This dust collector is located indoors in the Blend Room immediately adjacent to where employees work. There is electrical equipment in this room that could produce an ignition source, such as rotating blender motors. This dust collector does not have a deflagration venting to a safe area exposing the employees to the hazard of fire and explosion. Violation occurred on or around May 12, 2022 to the present.
Recent events (2)
- — I (S) $7252
- — Z (S) $7252
1910.132 D02
- Issued
- Nov 7, 2022
- Abate by
- Jan 3, 2023
- Penalty
- Initial $7,252 · Current $3,593 Reduced
9130
General-duty citation text
29 CFR 1910.132(d)(2):The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment: a) Workplace, 25 Rizzolo Road, Kearny, NJ In the workplace where the employer directs employees to blend dye powders in rotating drums in the Blend Room and requires the use of PPE including Full Face 3M respirators, Tyvek, gloves, and rubber boots, and where employees in the Liquids Room use chemicals that include Spectra Malachite Green Liquid and 15% Aqua Ammonia that is corrosive, the employer did not develop and certify a written hazard assessment. Violation occurred on or about May 9, 2022
Recent events (2)
- — I (S) $3593
- — Z (S) $7252
1910.134 E01
- Issued
- Nov 7, 2022
- Abate by
- Dec 1, 2022
- Penalty
- Initial $5,801 · Current $3,500 Reduced
9130
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Workplace, 25-31 Rizzolo Rd., Kearny, NJ 07032 The employer did not provide a medical evaluation to determine the employee's ability to use a respirator for employees required to wear Full Face 3M respirators and PAPR to blend dye powders in rotating drums in the Blend Room. Violation occurred on or about May 9, 2022
Recent events (2)
- — I (S) $3500
- — Z (S) $5801
1910.134 F02
- Issued
- Nov 7, 2022
- Abate by
- Dec 1, 2022
- Penalty
- Initial $0 · Current $0
9130
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: The employer did not provide a fit test to determine the employee's ability to use a respirator for employees required to wear Full Face 3M respirators and PAPR to blend dye powders in rotating drums in the Blend Room. Violation occurred on or about May 9, 2022
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K01
- Issued
- Nov 7, 2022
- Abate by
- Dec 1, 2022
- Penalty
- Initial $0 · Current $0
9130
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not provide effective training that covered the required elements in 1910.134(k)(1)(i) through 1910.134(k)(1)(vii): Workplace, 25-31 Rizzolo Rd., Kearny, NJ 07032 The employer did not provide training in elements of proper respirator use including but not limited to, maintenance and correct cartridges, to the employees required to wear Full Face 3M respirators and PAPR to blend dye powders in rotating drums in the Blend Room. Violation occurred on or about May 9, 2022
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 E02
- Issued
- Nov 7, 2022
- Abate by
- Jan 17, 2023
- Penalty
- Initial $10,151 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.305(e)(2): Switches, circuit breakers and switchboards installed in wet locations were not enclosed in weatherproof enclosures: Workplace, 25-31 Rizzolo Rd. Kearny , NJ 07032 a) In the Liquids Room, there is a Seimens Electrical Switch that is 240 Volts that controls equipment including mixing motors. It is immediately behind and adjacent to mixing vats that employees spray with water to clean and that produces aqueous liquid splashing. It is not designed for use in wet or damp locations. b) In the Liquids Room, there is an Eaton Circuit Breaker enclosure that houses Breakers 7, 5 and 9 that controls equipment including mixing motors . It is immediately behind and adjacent to mixing vats that employees spray with water to clean and that produces aqueous liquid splashing. It is not designed for use in wet or damp locations. c) In the Blend Room, there is a Cutler-Hammer Electrical Switch that controls blending mixers. It is subject to water spray during water spray cleaning of the blending mixers. It is not designed for use in wet or damp locations. Violation occurred on or about May 12, 2022
Recent events (2)
- — I (S) $5000
- — Z (S) $10151
1910.305 J02 IV
- Issued
- Nov 7, 2022
- Abate by
- Jan 17, 2023
- Penalty
- Initial $10,151 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location: a) Facility In the Liquids Room, there is a 120 Volt receptacle installed immediately behind and adjacent to mixing vats that employees spray with water to clean and that produces aqueous liquid splashing. It is not designed for wet or damp locations. Violation occurred on or about May 12, 2022
Recent events (2)
- — I (S) $5000
- — Z (S) $10151
1910.1200 E01
- Issued
- Nov 7, 2022
- Abate by
- Dec 1, 2022
- Penalty
- Initial $5,801 · Current $3,500 Reduced
9130
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): For employees directed to blend dye powders in rotating drums in the Blend Room, the employer did not implement a written hazard communication program for employees who work with and blend various dye chemicals, including but not limited to Acid Red 52, that has been found to be mutagenic in hamster cell tests in vitro according to the SDS and Acid Red 18, a Mono Azo where these compounds are known according to research available that they can metabolize into more harmful carcinogenic substances . Violation occurred on or about May 9, 2022
Recent events (2)
- — I (S) $3500
- — Z (S) $5801
1910.1200 H03 II
- Issued
- Nov 7, 2022
- Abate by
- Dec 1, 2022
- Penalty
- Initial $0 · Current $0
9130
General-duty citation text
29 CFR 1910.1200(h)(3)(ii): Employee training did not include the physical and health hazards of the chemicals in the work area: a) Facility For employees directed to blend dye powders in rotating drums in the Blend Room, the employer did not train employees in the chemical hazards of the various dye chemicals they blend, including but not limited to Acid Red 52, that has been found to be mutagenic in hamster cell tests in vitro according to the SDS and Acid Red 18, a Mono Azo where these compounds are known according to research available that they can metabolize into more harmful carcinogenic substances . Violation occurred on or about May 9, 2022
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Spectra Colors Corp.
View Spectra Colors Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 424950)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345950489.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.