Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DWORAK CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DWORAK CONSTRUCTION, INC. in 203 FOREST AVE, OAK PARK, IL 60302 (NAICS 238160). OSHA activity number 345951768.

Watch Dworak Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Dworak Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
203 FOREST AVE
City
OAK PARK
State
IL
ZIP
60302
Mailing
1445 GENTRY RD, HOFFMAN ESTATES, IL 60169
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

6 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 16, 2022
Abate by
Sep 12, 2022
Penalty
Initial $3,108 · Current $3,108
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:     a) On May 11, 2022, employees were exposed to eye injury while operating a pneumatic nail gun without eye protection during roofing work.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $3108

1926.501 B13

Serious Gravity 10 1 instance 6 exposed
Issued
Aug 16, 2022
Abate by
Sep 12, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a)  On May 11, 2022, employees performing roofing work were exposed to fall hazards of up to approximately 32 feet.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4351

1926.502 D01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 16, 2022
Abate by
Sep 12, 2022
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(1): Personal fall arrest system connectors were not drop forged, pressed or formed steel, or made of equivalent materials:  a) On May 11, 2022, employees were exposed to fall hazards while using personal fall arrest system components containing connectors that were not drop forged, pressed or formed steel.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.502 D06 I

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 16, 2022
Abate by
Sep 12, 2022
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(6)(i): A snaphook not designed for such use was engaged directly to webbing, rope or wire rope:  a)  On May 11, 2022, employees were using a personal fall arrest life line that  had its locking snaphook engaged to the webbing of their harness  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.502 D15

Serious Gravity 10 4 instances 4 exposed
Issued
Aug 16, 2022
Abate by
Sep 12, 2022
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not independent of any anchorage being used to support or suspend platforms and/or were not capable of supporting at least 5,000 pounds (22.2 kN) per employee:  a)  On May 11, 2022, anchorages being used for attachment of personal fall arrest equipment were not installed so that they would be capable of supporting at least 5,000 pounds per employee attached.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0

1926.503 A01

Serious Gravity 10 1 instance 6 exposed
Issued
Aug 16, 2022
Abate by
Oct 3, 2022
Penalty
Initial $4,351 · Current $4,351
29 CFR 1926.503(a)(1):  The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:   a)  On or about May 11, 2022, employees were exposed to fall hazards while performing roofing work and the employer did not provide a training program to recognize fall hazards and the procedures to be followed in order to minimize those hazards.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4351

View DWORAK CONSTRUCTION, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345951768.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.